Not supported by SBC SWe Lite in this release.

 

Table of Contents
About this Page
  • This Interoperability Note describes how to configure a TDM port on a Mitel 3000 ICP PBX to integrate with the Sonus SBC Edge.  Also included is configuration information for integrating Exchange Unified Messaging to the Mitel PBX via SBC Edge.
Related Articles

Prerequisites

Requires Sonus SBC Edge Version 3.0

Mitel 3300 ICP PBX, Version 9.0.0.41, T1, QSIG

Interoperation Notes

The following extension numbers are used within this document:

•  UMS Pilot Extension: 2562
•  Extensions enabled for Microsoft Exchange Server UM: 5100 - 5199

PBX Configuration

Use the following configurations to interconnect the Mitel to SBC Edge.

  1. Ensure that your Mitel 3300 ICP PBX has the necessary T1 PRI Module to Support T1 QSIG by navigating to: System Configuration / Units/Modules / Units Configuration Display.

    Unit Configuration Display

    Dual T1/E1 Framer Configuration

    Dual T1/E1 Framer Port Configuration




  2. Create Class of Service for your QSIG trunk by using the following path to create a Class of Service for the QSIG trunk: System Configuration / Trunks / Class of Service Options Assignment.

    Class of Service Options 1

    Class of Service Options 2

    Class of Service Options 3

    Class of Service Options 4

    Class of Service Options 5

     

     

  3. Create a Link Descriptor Assignment by using the following path: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Link Descriptor Assignment.

    Link Descriptor Assignment

     

     



  4. Create a Digital Link Assignment by using the following path: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Digital Link Assignment.

    Digital Link Assignment

     

    Create Digital Link Assignment

     

     

  5. Add a MSDN-DPNSS-DASSII Trunk Circuit Descriptor by using the following path: System Configuration / Trunks / Digital Trunks / ISDN-PRI/MSDN-DPNSS-DASSII Trunk Circuit Descriptor.

    MSDN-DPNSS-DASSII Trunk Circuit Descriptor

    Create MSDN-DPNSS-DASSII Trunk Circuit Descriptor

     



  6. Create a Trunk Service Assignment by using the following path to create a Trunk Service Assignment: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Trunk Service Assignment.

    Create Trunk Service Assignment

     

     

  7. Assign Digital Trunks by using the following path to assign Digital Trunks: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Digital Trunk Assignment.

    Digital Trunk Assignment

    Digital Trunk Assignment Form

     



  8. Add a Trunk Group for QSIG Using the following path: System Administration / Automatic Route Selection / Trunk Group Assignment. Next, create a new trunk group for QSIG and add trunk group members.

    Add Trunk Group

    Trunk Group Members Form

     

     

  9. Add a Route Assignment by using the following path: System Administration / Automatic Route Selection / Route Assignment.

    Route Assignment

    Add Route Assignment

     

     

  10. Add a ARS Digits Dialed Assignment by using the following path to add ARS Digits Dialed Assignment: System Administration / Automatic Route Selection / ARS Digits Dialed Assignment.

    ARS Digits Dialed Assignment

    ARS Digits Dialed Assignment Form

     

     

  11. Under System Option Assignment, set the following fields as follows:
     
    1) Route Optimization Network ID: Select a unique number.
    2) DPNSS/QSIG Diversion Enabled: Select 'Yes'.

    System Option Assignment

     

     

  12. Use the TDM document to configure SBC Edge.

    •  Configuring TDM ports on SBC Edge

  13. Use the EUM integration document to finished the voicemail integration.

     Configuring SBC Edge with Exchange 2013



  • No labels