Not supported by SBC SWe Lite in this release.
Requires Sonus SBC Edge Version 3.0
Use the following to configure a SBC Edge TDM port to interconnect to another TDM port/device.
Connect to the SBC interface via your web browser.
Connect to SBC
Set the DS1 Type of the ports on your TDM card, either T1 or E1 depending upon your installation situation.
More information on the TDM port configuration parameters can be found at Managing Telephony Ports.
Set DS1 Port Type
Configure the TDM port parameters to match with your installation.
Configure TDM Port
Create a ISDN Signaling Group to process inbound calls from the TDM port.
More information on the TDM Signaling Group configuration parameters can be found at Managing ISDN Signaling Groups.
Create ISDN Signaling Group
Configure the ISDN Signaling Group to match the requirements of the incoming TDM signaling.
ISDN Signaling Group Details
Below is a diagram for configuring a TDM port to route to a SIP destination
Configuring TDM Port to Route to SIP Destination