Use the Flags window to configure redirecting capability flags in a Signaling Profile.
On the SBC main screen, choose a path:
Select the Signaling Profile you want to configure from the drop-down list. The Flags window is displayed.
This window displays parameters only when the Redirection Capability Flags option is enabled.
Use the following table when configuring the options and then click Save.
Flags Parameters:
Parameter | Description |
---|---|
Check Carrier Code Combination | When enabled, the SBC matches the carrier code in the call against the configured carrier codes in the Carrier Code Combination Profile.
|
Check Ingress Trunk Grp Redirection Capability | When enabled, the SBC checks for Ingress Trunk Group redirection capabilities.
|
Check Number Control Profile For Received Called Number | When enabled, the SBC checks the Number Control Profile for a match on the received called number.
|
Check Received Redirection Params | When enabled, the SBC checks for both the redirection capability and information parameters.
|
Check Redirection Cap of Number Used for Routing In Number Control Profile | When enabled, the SBC checks for redirection capabilities for the number used for routing.
|
Check SIP Indirect Dip And Username Translation Source Number | When enabled, the SBC checks whether the received request is a SIP Indirect DIP and whether it contains the Translation Source Number.
|
Create Called Directory Number in Egress Signal On Redirection | When enabled, the original called party is sent by the SBC as the Called Directory Number.
|
Skip Redirection On RACIndication Set | When enabled, if the Representative Area Code indicator is set to On in the JTI parameter, the SBC does not perform redirection.
|