Use this object to configure H.323 Signaling Ports.
Note
Each signaling port within an Address Context must use a unique IP address and port number combination.
Note
The SBC 5400 and SBC 7000 systems support creating IP Interface Groups containing sets of IP interfaces that are not "processor friendly" (i.e. carried on physical Ethernet ports served by separate processors). However, restrictions exist regarding the usage of such Interface Groups.
For complete details, refer to Configuring IP Interface Groups and Interfaces.
Command Syntax
% set addressContext <name> zone <name> h323SigPort <#> action <dryup | force> dryUpTimeout <0-1440> dscpValue <#> h225IpAddress <IPv4 address> h245IpAddress <IPv4 address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <#> state <disabled | enabled>
// Mandatory parameters:
h323SigPort <index #> action <force | dryUp> dscpValue <0-63> h225IpAddress <ip address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <1-65535> state <disabled | enabled>
// Non-mandatory parameters:
dryUpTimeout <0-1440> h245IpAddress <ip address>
Command Parameters
Overview
Content Tools