Use this object to configure H.323 Signaling Ports.
Each signaling port within an Address Context must use a unique IP address and port number combination.
The SBC 5400 and SBC 7000 systems support creating IP Interface Groups containing sets of IP interfaces that are not "processor friendly" (i.e. carried on physical Ethernet ports served by separate processors). However, restrictions exist regarding the usage of such Interface Groups.
For complete details, refer to Configuring IP Interface Groups and Interfaces.
Command Syntax
% set addressContext <name> zone <name> h323SigPort <#> action <dryup | force> dryUpTimeout <0-1440> dscpValue <#> h225IpAddress <IPv4 address> h245IpAddress <IPv4 address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <#> state <disabled | enabled>
// Mandatory parameters:
h323SigPort <index #> action <force | dryUp> dscpValue <0-63> h225IpAddress <ip address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <1-65535> state <disabled | enabled>
// Non-mandatory parameters:
dryUpTimeout <0-1440> h245IpAddress <ip address>
Command Parameters
Zone H.323 Signaling Port Parameters
Parameter | Length/Range | Description |
---|---|---|
action | N/A | Controls whether calls are forced off or allowed to dry up upon a mode out-of-service. Select any one of the option:
|
dryUpTimeout | 0-1440 | Dryup timeout (in minutes) when this H.323 Signaling Port is outOfService with dryup action. (default = 0). |
dscpValue | 0-63 | The DSCP value for packets from this H.323 Signaling Port. (default = 0). |
h225IpAddress | IPv4 | The H.225 IPv4 address of the H.323 Signaling Port. |
h245IpAddress | IPv4 | The H.245 IPv4 address of the H.323 Signaling Port. |
ipInterfaceGroupName | The IP interface group to be used by this Signaling Port. | |
mode | N/A | Operational mode for this H.323 Signaling Port.
|
portNumber | 1-65535 | TCP Port number of the H.323 Signaling Port. (default = 1720). |
| N/A | Administrative state of the H.323 Signaling Port.
|