Perform the procedures in the following workflow to configure the

Unable to show "metadata-from": No such page "_space_variables"
device for a basic SIP Trunk to SIP IP PBX application. The resulting configuration connects an existing LAN-side IP PBX host to a WAN-side Border Element host, such that internal callers can reach an outside Internet Telephony Service Provider (ITSP) and vice-versa. (Provisioning for a specific dial plan is beyond the scope of this workflow.)

For a complete illustration of the entire provisioning process, including sample outputs of the Setup Wizard, Network Interface provisioning, Static Route provisioning, and the Easy Configuration Wizard, refer to SIP Trunk Configuration for IP PBX Deployment.

Basic SIP Trunk to SIP IP PBX Application


Note

Throughout the procedures, links to

Unable to show "metadata-from": No such page "_space_variables"
customer documentation provide
Unable to show "metadata-from": No such page "_space_variables"
topics helpful in configuring your
Unable to show "metadata-from": No such page "_space_variables"
device.


ATTENTION

The IP addresses shown in the examples may conflict with an existing or planned production network. Consult with your network administrator for the IP addresses required for your specific deployment.

Prerequisites

  • Completion of the initial setup procedures per the Workflow for Initial Setup. This includes physically installing the device, configuring the initial platform settings (Setup Wizard), and installing the
    Unable to show "metadata-from": No such page "_space_variables"
    license.
  • Login access to the
    Unable to show "metadata-from": No such page "_space_variables"
    WebUI as user administrator (admin)

Workflow

Configure Network Interfaces

Use this procedure to manage the way the

Unable to show "metadata-from": No such page "_space_variables"
within the
Unable to show "metadata-from": No such page "_space_variables"
device interfaces with the external network.

The

Unable to show "metadata-from": No such page "_space_variables"
supports:

  • four system-created logical interfaces: the Administrative IP, Ethernet 1 IP, Ethernet 2 IP, and Ethernet 3 IP interfaces
  • user-created VLAN logical sub-interfaces
Tip

Refer to Managing Logical Interfaces within the

Unable to show "metadata-from": No such page "_space_variables"
documentation for additional
Unable to show "metadata-from": No such page "_space_variables"
information

The following table explains the nature of each of the logical interfaces.

Logical Interfaces for a SIP to SIP IP PBX Application

Logical InterfaceWhen and How ConfiguredPurpose
Admin IPSet during the execution of the Setup Wizard1,  under Swe-Edge Settings: Mgmt Host IP.

Provides access to the

Unable to show "metadata-from": No such page "_space_variables"
WebUI of the
Unable to show "metadata-from": No such page "_space_variables"
device

Ethernet 1 IPConfigured manually.Provides access to the LAN-side IP PBX
Ethernet 1.2626 IPConfigured manually.Provides a VLAN logical sub-interface to the LAN-side IP PBX 
Ethernet 2 IPConfigured manually.Not used in this SIP to SIP IP PBX application
Ethernet 3 IPConfigured manually.

Provides access to the WAN-side Border Element (Internet Telephony Service Provider, ITSP)

1 References to the Setup Wizard refer to the procedures in Running Setup Wizard, either for the

Unable to show "metadata-from": No such page "_space_variables"
stand-alone or
Unable to show "metadata-from": No such page "_space_variables"
High Availability deployment.

Start

  1. In the Web UI, click the Settings tab.
  2. Navigate to Networking Interfaces > Logical Interfaces.
  3. Configure each of the logical interfaces per your network plan.
    For field definitions, refer to Configuring and Modifying Logical Interfaces in the

    Unable to show "metadata-from": No such page "_space_variables"
    documentation.

Configure Static Routes

Use this procedure to configure static routes required by your

Unable to show "metadata-from": No such page "_space_variables"
device to communicate with remote networks.

In a production environment, static routes are mainly configured for routing from a specific network to another network that can only be accessed through a gateway (for a single path access or default route). When planning your network, consider these factors:

  • For smaller networks with just one or two routes, configuring static routing is preferable. This is often more efficient since a link is not being wasted by exchanging dynamic routing information.
  • For networks that have a LAN-side gateway on Voice VLAN or Multi-Switch Edge Devices (MSEs) with voice VLAN towards the SBC Edge, static routing configurations are not required.
Tip

Refer to Managing Static IP Route Tables within the

Unable to show "metadata-from": No such page "_space_variables"
documentation for additional
Unable to show "metadata-from": No such page "_space_variables"
information.

In the following example, two static routes are defined:

  • The first static route gives access to the SWe Edge WebUI through a VPN subnet.
  • The second static route gives access to SIPP servers on the WAN side of the
    Unable to show "metadata-from": No such page "_space_variables"
    device.

Start

  1. In the Web UI, click the Settings tab.
  2. Navigate to Protocols > IP > Static Routes.
  3. Configure each of the static routes per your network plan.
    For field definitions, refer to Creating Entries in a Static IP Route Table in the

    Unable to show "metadata-from": No such page "_space_variables"
    documentation.

Run the Easy Config Wizard

Use this procedure to configure the basic call routing framework for a SIP Trunk to SIP IP PBX application.

The 

Unable to show "metadata-from": No such page "_space_variables"
WebUI includes an Easy Configuration Wizard, which enables end-users to quickly configure settings for different deployment scenarios. Based on a template, you can configure items including:

  • an endpoint, with a defined user and provider
  • a routing scheme, with a routing configuration applied to the scenario
  • a country, with tone table parameters and emergency numbers for the chosen country
Note

Once you complete the Easy Config Wizard, you must apply additional provisioning before making calls. This includes changing entries to the Transformation Tables, Signaling Groups and Routing Tables according to the network topology and dialing plan unique to your particular deployment.

Tip

Refer to Working with SBC Easy Configuration within the

Unable to show "metadata-from": No such page "_space_variables"
documentation for additional
Unable to show "metadata-from": No such page "_space_variables"
information.

Start

  1. In the Web UI, click the Tasks tab.
  2. Navigate to SBC Easy Setup > Easy Config Wizard
  3. From the Step 1 menu, complete the fields for Scenario Parameters, SIP Trunk and IP PBX.
    For SIP Sessions, enter a value based on the license allocation for concurrent call sessions you ordered when you placed your

    Unable to show "metadata-from": No such page "_space_variables"
    order.
    For field definitions, refer to Configure a SIP Trunk With IP PBX in the
    Unable to show "metadata-from": No such page "_space_variables"
    documentation.

  4. Note

    The value entered for Scenario Description will be prefixed to all SBC configuration elements that the Easy Config Wizard creates.

    Example: If you enter SIP to SIP for the description, then the Call Routing tables for this deployment will be SIP to SIP: From IP PBX and SIP to SIP: From SIP Trunk.

    Example:

    PanelAreaFieldValue
    Scenario Parameters
    ApplicationSIP Trunk ↔ IP PBX
    Scenario DescriptionSIP to SIP
    Telephone CountryUnited States
    Emergency ServicesNone
    SIP PropertiesSIP Sessions100
    SIP Trunk
    NameOther SIP Trunk
    IP PBX
    Type

    Other IP PBX

  5. Click Next.
  6. From the Step 2 menu, complete the fields for SIP Trunk and IP PBX.
    For field definitions, refer to Configure a SIP Trunk With IP PBX in the

    Unable to show "metadata-from": No such page "_space_variables"
    documentation.
    Example:

    PanelFieldValue
    SIP Trunk: Other SIP TrunkBorder Element Server10.230.98.141
    ProtocolUDP
    Port Number5060
    Use Secondary Border Element ServerDisabled
    IP PBX: Other IP PBXHost

    10.230.98.142

    Protocol

    UDP

    Port Number

    5060

    Use Secondary Server

    Disabled

  7. Click Next.
  8. From the Step 3 menu, examine the SBC Setup Configuration Summary.
    Click Previous to make a change in a previous step.
    Click Finish when you are satisfied with the entries.
  9. After clicking Finish, click OK when you are ready to continue.
    Note that after clicking Finish, a confirmation message appears stating that a standard configuration is being applied and that you will need to configure additional parameters (especially for Transformation Tables, Signaling Groups and Routing Tables) before making calls. Click OK when you are ready to complete the Easy Configuration process.