This section describes how to configure the DS1 port types (T1/E1) on the SBC 1000/2000 system. Using this feature sets the DS1 ports on the SBC 1000/2000 to either T1 or E1. In most geographical area only T1 or E1 is available. However, in some countries both are available and the SBC may be required to support both simultaneously.
SBC 2000 T1/E1 Ports
T1/E1 ports on the SBC 2000 are provided via removable T1/E1 PSTN Interface cards. The SBC 2000 supports up to two T1/E1 PSTN Interface cards with a maximum of 16 physical T1/E1 ports. The T1/E1 PSTN Interface cards are available with 8 T1/E1 ports licensed individually. Each SBC 2000 T1/E1 PSTN Interface Card provides two four-port spans, each span is individually configurable as either T1 or E1.
SBC 1000 T1/E1 Ports
T1/E1 ports on the SBC 1000 are provided via two non-removable module cards (each card provides two ports; each port is licensed individually).
Two T1/E1 Ports on the SBC 1000 are available only if running SBC 1000 v2 hardware and SBC Release 6.0.0 or later; previous releases support one T1/E1 port only.
Setting the Port Type
To set the port type:
Click the Set DS1 Port Type text at the top of the Port Table View page.
- Select either T1 or E1 from the ports menu(s).
- Click OK.