In this section:
This section specifies the Redirect parameters for Egress Ip Attributes. On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Ip Signaling Profile > Egress Ip Attributes > Redirect. The Redirect window is displayed. On the Redirect window, choose the Ip Signaling Profile as DEFAULT_H323 to view the Redirect parameters for H323 Trunk Group. Figure 1: Trunk Provisioning - Egress Ip Attributes H323 Redirect There are no Redirect parameters for DEFAULT_H323 type of Egress Ip Attributes. On the Redirect window, choose the Ip Signaling Profile as DEFAULT_SIP to view the Redirect for SIP Trunk Group. Figure 2: Trunk Provisioning - Egress Ip Attributes SIP Redirect The following fields are displayed: Table 1: Egress Ip Attributes SIP Redirect Parameters Parameter Description Use this object to control SIP redirection: Select one of the following to control processing of contacts received in SIP Redirects: Make the required changes and click Save at the right hand bottom of the panel to save the changes made.To View and Edit Redirect
DEFAULT_H323
DEFAULT_SIP
Mode
Accept Redirection
– (default) Multiple redirection are allowed.Allow Single Redirect Attempt
– Only a single Redirect is allowed per route. Additional Redirects cause crankback to be performed.Reject Redirection
– If a Redirect is received, crank back is performed.Contact Handling
Merge Received Contacts
– Contacts received in Redirects are ordered by q-value and inserted at the head of the list of untried contacts.Purge Existing Contacts
– Contacts received in Redirects are ordered by q-value and replace untried contacts.