In this section:
The request alarms
command is available from both system-level and configure modes, and is used to accomplish the following activities:
The command syntax to clear or set alarms is listed below.
> request alarms clear current alarmId <integer> deleteMatchingAlarms <no | yes> history current comment alarm id <integer> text <operator comment> state alarm acknowledgeState <acknowledge | unAcknowledge> id <integer>
To clear all current/outstanding alarm(s):
> request alarms clear current result success reason All current/outstanding alarms have been purged
To clear all alarms from the history buffer:
> request alarms clear history Deleted all alarm entries in history-table
To set the acknowledgeState of alarm Id 222 to 'acknowledge':
% request alarms current state alarm id 222 acknowledgeState acknowledge result success reason [ok]