DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
The following procedure describes how to use the Windows PC/terminal to connect the SBC 5000 series serial port and assign it an IP address.
Execute the bmcInit.sh command. Assign the BMC management IP address, netmask, default gateway and NTP time server IP address.
Example:
# sh bmcInit.sh ************************************************************* *** BMC Initialization *** ************************************************************* Enter BMC management IP (aaa.bbb.ccc.ddd) : 10.2.12.181 Enter BMC management netmask (aaa.bbb.ccc.ddd): 255.255.255.0 Enter default gateway IP (aaa.bbb.ccc.ddd) : 10.2.12.1 Enter NTP time server IP (aaa.bbb.ccc.ddd) : 10.1.1.2 Enter advanced configuration? <y/n>:n Note: The advanced configuration is used exclusively to configure static routes. For this installation example, enter "n".
Verify your entries.... bmcIpAddr = 10.2.12.181 bmcNetmask = 255.255.255.0 gatewayIpaddr = 10.2.12.1 ntpServerIpaddr = 10.1.1.2 Ok to apply configuration? <y/N>:y Restarting NTP and network services .... Setting up IP spoofing protection: rp_filter. Reconfiguratoin network interfaces...done. Restarting NTP server: ntpd... done. Note: Reboot the BMC after completing the process.