This section provides instructions to perform an upgrade on the EdgeMarc firmware using EdgeView. To perform these actions on EdgeView, follow the steps below.
To set up an upgrade firmware repository:
To locate the EdgeMarc VOS files on the FTP server, follow the steps given below:
Base path is the absolute path to which the EdgeMarc VOS files are located. By default, the base path is in root.
To add a firmware repository on the EdgeView device, follow the steps given below:
Choose System > Firmware Repositories.
Click ADD REPOSITORY on the top right corner. The Add Repository page appears.
On the Add Repository page, enter the repository details of the selected device from its FTP server and enable the Map to Unassigned collection check-box.
Click Add Repository. The Upgrade page appears.
Select Map Versions. The Map Versions dialog box appears, where you can select the latest GA build version for upgrading from EdgeView to EdgeMarc.
To add a collection for the upgrade firmware, follow the steps given below:
Choose Devices > Collections.
Click ADD COLLECTION on the top right corner. The Add Collection page appears.
For more details on EdgeView Collections, refer to Managing Collections.
To add the required EdgeView device to the created collection, follow the steps given below:
Choose Devices > List.
Under the Bulk Actions menu, select Move to Collection.
On the Move to Collection page under Choose collection, select the created collection.
Enable the Send notification once Move is completed check-box if you want to receive notifications.
Click Move 1 Device. You are prompted to confirm this action.
Click MOVE NOW to confirm the action. The Action Log page appears.
For more details on EdgeView Collections, refer to Managing Collections.
To perform the firmware upgrade, follow the steps given below:
On the Action Log page, click on the device that you added to the collection.
On the Device Overview page under the ACTIONS menu, select Upgrade Firmware.
The Upgrade Firmware page appears.
Under the Included Devices table, select the firmware version to which you want to upgrade the device (see Upgraded Firmware page).
Enable the Send notification once Upgrade is completed check-box if you want to receive notifications.
Time Zone – Choose whether the time is to be calculated based on Local Time Zone or UTC.
Click UPGRADE 1 DEVICE (see Upgraded Firmware page). You are prompted to confirm the upgrade.
Select UPGRADE NOW to upgrade the selected device (see Confirm Upgrade).
If you scheduled this action to be performed at a later point in time, you can edit this action at any point before the scheduled time. To edit, go to Jobs > Scheduled Jobs and click the Edit icon corresponding to this action. For more details on scheduling and editing a job, refer to Scheduling Jobs in EdgeView.
Devices that are not moved to the created collection cannot be upgraded using the above steps. If you try to upgrade such a device, the following message is displayed:
"This action will not be performed on these devices due to insufficient permission or other conditions. See details in table."