About this Resource

Defines a CAS E and M Signaling Profile to be used in a CAS Signaling Group

REST API Methods for this Resource

Resource Schema

Configuration

Parameter Name Required Service Affecting Data Type Default Value Possible Values Description
DescriptionNoNostringnone64 - Max Length A description of the profile.
OrientationYesNoEnum0Possible values:
  • 0 - eCas_User
  • 1 - eCas_Network
Set the CAS signaling orientation. Set to User if connected to a PSTN; Set to Network if connected to a PBX.
IncomingStartDialYesNoEnum0Possible values:
  • 0 - eCas_EmWinkStart
  • 1 - eCas_EmImmediateDialing
Used to configure the type of E&M protocol for incoming calls.
OutgoingStartDialYesNoEnum0Possible values:
  • 0 - eCas_EmWinkStart
  • 1 - eCas_EmImmediateDialing
Used to configure the type of E&M protocol for outgoing calls.
DTMFOnTimeYesNoint100Possible values:
  • 45 - Minimum
  • 250 - Maximum
Used to set how long DTMF tones are on. The value specifies the time in milliseconds.
DTMFOffTimeYesNoint100Possible values:
  • 45 - Minimum
  • 250 - Maximum
Used to set how long DTMF tones are off. The value specifies the time in milliseconds.
InterDigitTimeoutYesNoint500Possible values:
  • 250 - Minimum
  • 30000 - Maximum
Used to set the timeout time between dialed numbers. The value specifies the timeout period in milliseconds.