Parameter Name | Required | Service Affecting | Data Type | Default Value | Possible Values | Description |
---|---|---|---|---|---|---|
Description | No | No | string | none | 64 - Max Length | A description of the profile. |
Orientation | Yes | No | Enum | 0 | Possible values:
| Set the CAS signaling orientation. Set to User if connected to a PSTN; Set to Network if connected to a PBX. |
IncomingStartDial | Yes | No | Enum | 0 | Possible values:
| Used to configure the type of E&M protocol for incoming calls. |
OutgoingStartDial | Yes | No | Enum | 0 | Possible values:
| Used to configure the type of E&M protocol for outgoing calls. |
DTMFOnTime | Yes | No | int | 100 | Possible values:
| Used to set how long DTMF tones are on. The value specifies the time in milliseconds. |
DTMFOffTime | Yes | No | int | 100 | Possible values:
| Used to set how long DTMF tones are off. The value specifies the time in milliseconds. |
InterDigitTimeout | Yes | No | int | 500 | Possible values:
| Used to set the timeout time between dialed numbers. The value specifies the timeout period in milliseconds. |