You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

In this section:

Use the admin object to configure system administration related parameters in the 

Unable to show "metadata-from": No such page "_space_variables"
system. You can configure audit log state, system location, IP version used, password rules and other parameters. 

Command Syntax

Command syntax for the set and request commands is shown below.

Set Command Syntax

See Set Command Parameters for parameter descriptions.

% set system admin <SYSTEM NAME> 
	accountManagement
		accountAging
			accountAgingPeriod <30-180>
			state <disabled | enabled>
		bruteForceAttack
			allowAutoUnlock <disabled | enabled>
			consecutiveFailedAttemptAllowed <1-10>
			state <disabled | enabled>
			unlockTime <30-3600 seconds>
		maxSessions <1-5>
		passwordAging
			passwordAgingPeriod <30-180>
			passwordExpiryWarningPeriod <3-14> 
			state <disabled | enabled>
		sessionIdleTimeout 
			idleTimeout <1-120>
			state <disabled | enabled>
	auditLogState <disabled | enabled>
	banner <system name>
		ackBanner <disable | enable>
		bannerText <text>
	cliSetWarningSupport <disabled | enabled>
	contact <contact_info>
	dod
		cliAccess <disabled | enabled>
		mode <disabled | enabled>
		pmAccess <disabled | enabled>
	dspMismatchAction <preserveCapacity | preserveRedundancy>
	externalAuthenticationEnabled <false | true>
	fips-140-2 mode <disabled | enabled>
	localAuthenticationEnabled <false | true>
	location <location_info>
	passwordRules 
		maximumRepeatingCharsCount <#>
		minimumDiffWithOldPassword <#>
		minimumLength <#>
		minimumNumberOfDigits <#>
		minimumNumberOfLowercaseChars <#>
		minimumNumberOfOtherChars <#>
		minimumNumberOfUppercaseChars <#>
		passwordHistoryDepth <#>
	rest state <disabled | enabled>
	standbyServerState <disabled | enabled>
	utilMonitorStatsInterval <#>
	utilMonitorStatsNumOfPastInterval <#> 

Request Command Syntax

See Request Command Parameters for parameter descriptions.

% request system admin <SYSTEM NAME>
	identify duration <0-255 seconds>
	loadConfig
		allowOldVersion <no | yes>
		filename 
	reGenerateSshRsaKeys
	reKeyConfdEncryptionKeys
	removeSavedConfig fileName <filename>
	restart
	revertSoftwareUpgrade revertMode <forced | normal>
	saveConfig fileNameSuffix <suffix>
	softReset
	switchover
	zeroizePersistenKeys

Command Parameters

Set Command Parameters

System Admin Parameters (set)

Parameter

Length/Range

Description

admin

N/A

Use this object to specify system name.

accountManagementN/A

Use this feature to manage system level account and password related settings.

  • accountAging – Use this parameter to enable account aging, and to specify the account expiration duration.
    • accountAgingPeriod – The number of days to elapse, after which the account is locked if left unused (range: 30-180 / default = 30).
    • state – Set flag to "enabled" to enable account aging system-wide.
      • disabled
      • enabled (default)
  • bruteForceAttack – Configuration for defense against brute force OAM password guessing attempts.
    • allowAutoUnlock – Enable Auto Unlock of an account blocked due to consecutive wrong password attempts.

      • disabled (default)
      • enabled
    • consecutiveFailedAttemptAllowed – Number of consecutive failed login attempts allowed before account is locked. As a safety measure, the system will not lock out the last/only active Administrator user on 

      Unable to show "metadata-from": No such page "_space_variables"
      platform. (range: 1-10 / default = 3)

      You must first set state to 'disabled' before changing the value of consecutiveFailedAttemptAllowed.

    • state – Enable/disable defense against brute force OAM password guessing attempts

      • disabled (default)
      • enabled
    • unlockTime – If allowAutoUnlock flag is enabled, this parameter specifies the time (in seconds) to elapse before a locked account automatically unlocks. (range: 30-3600 / default = 30)

  • maxSessions – Maximum number of simultaneous sessions allowed per user (range: 1-5 / default = 2).
  • passwordAging – password expiration related configuration.
    • passwordAgingPeriod – The number of days to elapse, after which a password expires (range: 30-180 / default = 90).

    •  passwordExpiryWarningPeriod – The number of days prior to the password expiry date on which the user receives a warning to change the password (range: 3-14 / default = 12).

    • state – Use this flag to enable/disable password aging feature.

      • disabled
      • enabled (default)
  • sessionIdleTimeout – Session idle timeout related configuration.
    • idleTimeout – The amount of idle time, in minutes, to elapse before ending a session due to inactivity (range: 1-120 / default = 10).
    • state – To use this feature, set this flag to "enabled".
      • disabled
      • enabled (default)

auditLogState

N/A

Use this flag to specify the management audit log state.

  • disabled
  • enabled (default)

banner

1-23

Use this parameter to customize the post-login banner from EMA and CLI applications.

  • ackBanner – Enable flag to require user to acknowledge (accept) the banner before gaining access to the system each time the user logs into the system.
    • disabled (default)
    • enabled 
  • bannerText  – Use this parameter to specify the banner text to display when users login to EMA and CLI applications.

"Field Service" and "Operator" user types are not allowed to change the Login Banner configuration.

cliSetWarningSupport

N/A

When this flag is enabled, warning prompts are configured for the "set" command.

  • disabled
  • enabled (default)

contact

N/A

Use parameter to specify system contact information. (default is "Unknown")

dodN/A

Use this object to enable DoD mode, and to enable/disable CLI and/or EMA access for temporary troubleshooting and diagnostics.

  • cliAccess – Use this flag to temporarily enable CLI for troubleshooting and diagnostic while the SBC is in DoD mode.
    • disabled (default)
    • enabled
  • mode – Use this flag to enable/disable DoD Mode.
    • disabled (default)
    • enabled
  • pmAccess – Use this flag to temporarily enable EMA's Platform Mode for troubleshooting and diagnostic while the SBC is in DoD mode.
    • disabled (default)
    • enabled

Enabling CLI and/or EMA for DoD mode lowers the security posture of the SBC. Remember to disable CLI and PM access once troubleshooting and/or diagnostics is completed.


dspMismatchActionN/A

Use this parameter to specify the action to take if a DSP mismatch is detected between the active and standby servers. 

  • preserveCapacity – The Active 

    Unable to show "metadata-from": No such page "_space_variables"
    continues to use the extra DSP capacity, as needed, assuming appropriate session licenses are in place; partial redundancy is in effect.

    If a switchover occurs, calls using the extra, non-matching DSP capacity on Active are not protected during switchover (i.e. partial redundancy).

  • preserveRedundancy (default) – The Active automatically triggers a graceful dry-up in an attempt to align DSP hardware capabilities. Once dry-up completes, the Active SBC uses the protected, matching DSP capacity to preserve redundancy.

    During the dry-up period, active calls using the extra, non-matching DSP capacity are not protected in the event that a switchover occurs before the dry up completes.

externalAuthenticationEnabled

N/A

The confd CLI user information stored on remote RADIUS server is available for authentication.

  • false (default)
  • true
fips-140-2 modeN/A

 Use this object to enable FIPS-140-2 mode.

  • disabled (default)
  • enabled 

Once fips-140-2 mode is enabled, it cannot be 'disabled' through the configuration. A fresh software installation is required to set the FIPS-140-2 mode back to 'disabled'.

For complete details of configuring the 

Unable to show "metadata-from": No such page "_space_variables"
for FIPS 140-2 compliance, see Enabling SBC for FIPS 140-2 Compliance page.

localAuthenticationEnabled

N/A

The confd CLI user information stored locally is available for authentication.

  • false
  • true (default)

location

N/A

Specifies the physical location of the system.

passwordRules

N/A

The rules implementing confd user password policy.

  • maximumRepeatingCharsCount – Maximum number of consecutive repeating characters in the password. (range: 3-16 / default = 3).
  • minimumDiffWithOldPassword  – The minimum differences between the old and the new passwords (range 1-8 / default - 4).
  • minimumLength – Minimum number of characters that should be present in the password. (range: 8-24 / default = 8)
  • minimumNumberOfDigits – Minimum number of digits that should be present in the password. (range: 0-16 / default = 1)
  • minimumNumberOfLowercaseChars – Minimum number of lower case characters that should be present in the password. (range: 0-16 / default = 1)
  • minimumNumberOfOtherChars –-Minimum number of non-alpha-numeric characters that should be present in the password. (range: 0-16 / default = 1)
  • minimumNumberOfUppercaseChars – Minimum number of upper case characters that should be present in the password. (range: 0-16 / default = 1)
  • passwordHistoryDepth –The number of latest passwords that should be prevented from re-use. (range: 0-10 / default = 4)
restN/A

Enable this flag to allow

Unable to show "metadata-from": No such page "_space_variables"
to support REST API. For REST API details, see REST API User's Guide.

  • disabled (default)
  • enabled

standbyServerState

N/A

Use this flag to manually enable or disable standby server if the active server fails.

  • disabled
  • enabled (default)

utilMonitorStatsInterval

5-60

Specifies time interval for system resource monitoring statistics. This parameter defines the range of timer interval in minutes used by configuration management for measuring the statistics of certain resources. (default = 15).

Note

If using the EMS in your network, configure EMS PM data collection intervals for the SBC to be both:

  • Equal to or greater than the SBC intervals size, and
  • Not less than the SBC interval size multiplied by the SBC number of intervals.

Refer to Insight EMS User Guide for configuration details.

utilMonitorStatsNumOfPastInterval

1-12

The number of past intervals that can be configured for retrieving the statistics data. (default = 4).

Request Command Parameters

System Admin Parameters (request)

Parameter

Length/Range

Description

identify

0-255

Turn on/off the locator LED of the specified server for the amount of time set with the duration sub-parameter below.

  • duration – The duration (in seconds) to illuminate the locator LED of specified server. The LED illuminates for the specified number of seconds and then extinguishes. A duration of "0" turns off the locator LED and a duration of "255" turns on the locator LED indefinitely. If the duration is not specified, 15 seconds is set as the default value.

loadConfig

N/A

Load saved configuration and restart the system without rebooting the servers.

  • allowOldVersion – This option is only intended for use to override checks for older releases which do not identify their version. In this case, the follow error results. Follow the instructions given:

    "There is no version identifier on the saved file. Use the allowOldVersion parameter only if you are sure the version of the saved configuration file is compatible with the running software version."
    • no
    • yes
  • filename – Enter the configuration file to load.

In a redundant system, using loadConfig restarts both CEs.

If "reason Configuration file version not compatible with current software version. matrixFileNotAvailable" error is returned, the lswuMatrixSBX5000.bin/lswuMatrixSBX5000.txt file is missing from the/opt/sonus directory. You must must restore these files from the release package of the currently running software with the name pattern of "sbc-V0X.YY.ZZRQQQ.x86_64.tar.gz". Unzip and untar the current release's tar.gz file in that directory, return to the CLI and perform the command again.

reGenerateSshRsaKeysN/AUse this control to regenerate all SSH keys.
reKeyConfdEncryptionKeysN/A

Use this control to regenerate system configuration database encryption keys.

Unable to show "metadata-from": No such page "_space_variables"
recommends backing up current encrypted parameters in plaintext, if possible. 
Unable to show "metadata-from": No such page "_space_variables"
further recommends performing a full configuration backup immediately after this activity has successfully completed.

removeSavedConfig

N/A

Remove the saved configuration from the system.

  • fileName – Specify filename of configuration to remove from the system.

restart

N/A

Restart system (all CEs).

revertSoftwareUpgrade

N/A

Use this control to revert the last live software upgrade using one of the following selectable revert modes:

  • revertMode
  • forced
  • normal

saveConfig

N/A

Save the current configuration.

  • fileNameSuffix – Use this parameter to specify the filename suffix to use when saving the configuration.

softReset

N/A

Restart the applications on the system without rebooting the server(s).

switchover

N/A

Perform a switchover of the management applications and restart all applications on currently active server.

zeroizePersistenKeysN/A

Use this control to securely erase all persistent CSPs from the system. The 

Unable to show "metadata-from": No such page "_space_variables"
server reboots after confirmation.

Command Examples

The following example displays system administrative information:

admin@sbx1% show system admin
admin sbx1 {
    auditLogState       enabled;
    dspMismatchAction   preserveRedundancy;
    passwordRules {
        minimumLength                 8;
        minimumNumberOfUppercaseChars 1;
        minimumNumberOfLowercaseChars 1;
        minimumNumberOfDigits         1;
        minimumNumberOfOtherChars     1;
        passwordHistoryDepth          4;
        maximumRepeatingCharsCount    3;
        minimumDiffWithOldPassword    4;
    }
    fips-140-2 {
        mode disabled;
    }
    dod {
        mode disabled;
    }
} 

The following example turns on locator LED for 60 seconds:

% request system admin SBC01 identify duration 60  
result success  
reason Identifying server(s)...  
[ok][2012-12-28 08:46:19] 

The following example sets the Banner content to require user acknowledgement:

% set system admin SBC01 banner ackBanner enabled bannerText "This computer system, including all related equipment and network devices (including Internet access), are provided for authorized use only"
% commit

The following example uses the Account Management feature to accomplishes the following actions:

  • Allows a locked account to unlock after five minutes
  • Enables 
    Unable to show "metadata-from": No such page "_space_variables"
    to defend against brute force attacks
  • Sets the number of consecutive failed attempts to "3"
% set system admin MYSBC accountManagement bruteForceAttack state enabled allowAutoUnlock enabled consecutiveFailedAttemptAllowed 3 unlockTime 300

% show system admin MYSBC accountManagement bruteForceAttack
state                           enabled;
consecutiveFailedAttemptAllowed 3;
allowAutoUnlock                 enabled;
unlockTime                      300;
  • No labels