In this section:
Use the GW Sig Port window to configure a signaling port for gateway-to-gateway (GW to GW) call signaling. The gateway-to-gateway signaling is a protocol that transports call signaling messages between SBC (and GSX) instances over a TCP connection and requires that an external PSX is part of the network. The SBC supports gateway-to-gateway signaling on all platforms, including virtualized SBC SWe deployments.
The parameters to define the GW signaling port differ based on your type of the SBC platform. For cloud-based deployments of SBC SWe (I-SBC or D-SBC), the parameters include IP Var so that the IP address for the port can be specified using a metavariable rather than a static IP address. For other SBC platforms, use the IP Address V4 or V6 parameter to enter a specific IP address.
The SBC supports a single GW signaling port at a time. The GW signaling port must be defined within the default address context and the defaultSigZone zone, and it must be assigned an index value of 1.
Each signaling port within an Address Context must use a unique IP address and port number combination.
The SBC 5400 and SBC 7000 systems support creating IP Interface Groups containing sets of IP interfaces that are not "processor friendly" (i.e. carried on physical Ethernet ports served by separate processors). However, restrictions exist regarding the usage of such Interface Groups.
For complete details, refer to Configuring IP Interface Groups and Interfaces.
View GW Sig Port
On the SBC main screen, go to Configuration > System Provisioning > Category: Base Provisioning > Signaling Ports > GW Sig Port.
The GW Sig Port window is displayed. The following figure shows the window for an I-SBC or D-SBC (cloud) deployment that includes the IP Var parameter.
The following figure shows the window for non-cloud deployment that includes the IP Address V4 or V6 parameter.
Create the GW Sig Port
To create a new GW Sig Port,
- Select default from the Address Context drop-down and defaultSigZone from the Zone drop-down.
- Click the New GW Sig Port on the GW Sig Port List panel.
The Create New Gw Sig Port window is displayed. The following example shows the parameters for an I-SBC or D-SBC deployment.
The following fields are displayed:
Edit the GW Sig Port
To edit any of the Gw Sig Ports in the list, click the radio button next to the specific Gw Sig Port name.
- Click the radio button next to the name of the entry you want to edit. The Edit Gw Sig Port window opens.
Change the variable value and click Save.
Delete the GW Sig Port
To delete a GW Sig Port,
- Click the radio button next to the name of the entry you want to delete.
- Click the delete icon (X) at the end of the row.
- Confirm the deletion when prompted.