Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.8.1.2.1.19.0.3 |
Description | This alarm indicates that the connection to the License Manager failed. |
Repetition | Repeats for each occurrence. |
Event Codes | EVENT_LICENSE_MANAGER_SERVER_CONNECT_ERROR |
Instance Fields |
|
Action | Check the IP address in the message and check connectivity to that address. |
Impact | The SBC will not be able to register with the EMS/RAMP. Note
If the SBC remains disconnected from the managing EMS/RAMP instance for an extended period of time, it will result in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact Ribbon Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance. |
Clearing | automatic; sonusCpLicenseManagerRegistrationSucceeded |