DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.3

Description

This alarm indicates that the connection to the License Manager failed.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_SERVER_CONNECT_ERROR

Instance Fields

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusServerIpAddress
  • sonusLicenseManagerGraceDaysLeft

Action

Check the IP address in the message and check connectivity to that address.

Impact

The SBC will not be able to register with the EMS/RAMP.

Note

If the SBC remains disconnected from the managing EMS/RAMP instance for an extended period of time, it will result in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact Ribbon Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.

Clearing

automatic; sonusCpLicenseManagerRegistrationSucceeded