1. In the WebUI, click the Settings tab.
  2. In the left navigation pane, go to Node Interfaces> Ports.

    Port Table View

To modify a Port:

Click the expand () Icon next to the entry you wish to modify.

Modify FXO Port

 

Identification/Status - Field Definitions

The Identification/Status Panel controls the network identity of the port and its administrative state (Up or Down). It also provides the port's current service status and when that status last changed.

Port Alias

Specifies an alias for the port. This text is configured by the operator for exclusive use by SNMP-based element and network management systems to assign a key to the port or interface, that is unique across the managed network. Examples would be "Node10Port5" and "VerizonPort5"

Admin State

Specifies the administrative state of the port.

Physical Layer - Field Definitions

Analog Line Profile

Selection of an Analog Line Profile enables you to change the impedance presented by the Sonus SBC 1000/2000 FXS ports. It should match the impedance of the specified country's Telco. Some countries use resistive impedance and some use complex impedance. For example, telephone companies in the United States use 600 ohm resistive impedance where as Australia uses 220 ohms in series with the parallel combination of 820 ohms and 120 nF.

Select a country from the drop down list. If the desired country or a similar country is not listed, select Other or Other European (TBR 21).

For FXO ports. The FXO ports MUST be calibrated to avoid audible echos on the line, reduced call quality, and Caller ID failure. See Calibrating FXO Ports,

Relative Profile Adjustments

  • Negative values represent signal attenuation (lower volume).
  • Positive values represent signal amplification (higher volume).

Receive Gain

Specifies the number of decibels to boost or attenuate the level of signal coming into the SBC on an FXO port. The default value of 6 dB compensates for the loss on an FXO line coming in from the local PSTN.

Increasing the receive gain could result in failure of caller ID and dtmf detection by the SBC.  

Valid range:  -10 to +10. Default value: +6. 

Transmit Gain

Specifies the number of decibels to boost or attenuate the level of the signal leaving the SBC on an FXO port.  An unnecessary change in the signal level could cause call failures.

Valid range:  -10 to +10. Default value: 0

Ring Validation

Enables and disables ring validation by the FXO analog port.

Maximum Ring Frequency

Specifies the upper frequency limit used for ring validation by analog FXO port.

Minimum Ring Frequency

Specifies the lower frequency limit used for ring validation by analog FXO port.

Ring Detection Threshold

Specifies the RMS ring voltage, above which ring detection is guaranteed.