This article describes the steps necessary to configure the SBC Edge (SBC) for SIP Trunking using Multiple IP Interface support – available in since UX Release 1.0.2:
A typical use case scenario for the Multiple IP Interface support is:
The SBC is connected to both a public network and a private (Enterprise) network, acting as a Session Border Controller (SBC) which effectively hides the topologies, IP addressing, signaling attributes and policies established between these two networks from each other. Calls from one network to the other are terminated on SBC (i.e. at the network border) and SBC establishes a different call on the other network, and enables end-to-end conversation.
In this example, the SIP trunking provider and the SBC are connected using the 10.51.100.X
network. The enterprise has a IP range of 134.56.225.X
. The SBC's main application bridge is configured to 134.56.225.202
which is the default interface and has the default IP route pointing to it. The signaling and media packets for calls to and from OCS and LAN-1 endpoints will use 134.56.225.202 as the IP address of SBC.
When calls are established over the SIP trunk, LAN-2 interface is used. In this case the SIP calls must use the interface IP of 10.51.100.89
for the SIP messaging, SIP source IP address and RTP source IP address. This allows SBC to bridge the networks for calls and not simply route the IP packets.
The cleanest solution is to configure a single SIP Signaling Group for each network. The SIP SG pointing towards the ISP network should refer to LAN-2 interface. LAN-2 should be placed in ROUTED mode with an IP address in the 10.51.100.89/24
range. The SIP SG pointing to the Enterprise network should use the Application-IP interface, which is the default.
Topology |
---|
This article assumes that a PSTN - SBC - OCS 2007 R2 configuration is already in place, therefore it is unnecessary to configure Media Profiles, Media List, SIP Profiles, SIP Server Tables, Tone Table, Telephony Mapping Table in this exercise.
From the SIP Trunking with Multiple IP configuration point of view, the following items must be configured in the SBC:
Configure the public IP address 10.51.100.89
in the SBC. In the WebUI, access Tasks and select Modify Ethernet IP Address.
The LAN Port 1 134.56.225.202
is already configured on the node which you'd be using to URL into WebUI. Following screenshot depicts the verification of LAN 1 configuration:
Configure the public IP address of 10.51.100.89
in theSBC. In the WebUI, access Tasks and select Modify Ethernet IP Address.
There are 4 different transformations used in this exercise:
There are 3 different Call Routing Table entries used in this exercise:
This signaling group refers to the IP subnet used between SBC and the SIP trunking provider. There are two subcases here.
If there is a NAT device between SBC and the SIP-trunking peer, then NAT Traversal must be set to STATIC NAT and the public IP address of the NAT 20.40.60.89
must be specified as the Application IP. In addition, the NAT device should be configured such that it translates between the private address of 10.51.100.89
and the public address of 20.40.60.89
.
If there is no NAT device between SBC and the SIP-trunking peer, then NAT Traversal must be set to NONE as shown below:
The previous steps complete the necessary configuration requirements for implementing the Multiple IP feature on SBC Edge 1000/2000. However, if deploying a Sonus SBC SWE Lite, in addition to previous steps perform the following step to complete the Multiple IP feature support on Sonus SBC SWE Lite.