In this section:

The PSTN Hybrid Appliance table includes the state of a specific PSTN Hybrid Appliance. Entries can viewed only.

Please note the following:

  • The Update Schedule feature uses the ASM (SbcComms) and the Office 365 Tenant credentials configured in the Prepare CCE tab on the CCE wizard (refer to Configuring the SBC Edge for a Single CCE); it uses this resource to interact with the Office 365 Tenant.
  • If CCE configuration has not been completed, the WebUI will display an error message (For configuration, refer to Configuring the SBC Edge for a Single CCE). 
  • An error message is displayed if the SBC fails to connect to Office 365 with the current credentials; this occurs if wrong credentials are entered or if the credentials are changed on the Office 365 portal.

Viewing PSTN Hybrid Appliance

  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, go to Office 365 Cloud Connection Edition> Update Schedule
  3. From the tabbed panel, select PSTN Hybrid Appliance.
  4. Click on the desired entry. See PSTN Hybrid Appliance - Column Definitions.

     

    View PSTN Hybrid Appliance

PSTN Hybrid Appliance Window - Column Definitions

Name

The name of the appliance. For example: ASM141.

Site Index

References the site where the Appliance is attached.

Maintenance Mode

If set to True, service resilience detection is off, and no checks for Bits and OS updates will run; this enables administrators to make manual maintenance changes on the host machine.

If set to False, service resilience detection is on, along with checks for Bits and OS updates. 

Status

Displays the status of the appliance. For example: Running or Upgraded.

Version

Displays version of the appliance. For example: 2.0.0.

Primary Key

Internal index for sorting, Ribbon use only.