The Ribbon Application Management Platform can launch an
With the Ribbon Application Management Platform enabled, the
If a timeout results in the runtime status not being retrieved, then the
Requirements
To enable the Ribbon Application Management Platform, you must configure the Ribbon Application Management Platform panel (see the following procedure) according to your
- Unable to show "metadata-from": No such page "_space_variables"- Configure the Management IP address or FQDN.
- Unable to show "metadata-from": No such page "_space_variables"- Configure the Management IP address or FQDN and the Management ID.
When you enter the Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
Configure the Unable to show "metadata-from": No such page "_space_variables" for Ribbon Application Management Platform at Node-level
The Management ID is not applicable for SBC 1000/2000.
Use the following procedure to configure the
- Access a compatible web browser.
- In the browser, enter the IP address of the Unable to show "metadata-from": No such page "_space_variables"in the URL address bar. The Welcome to Ribbon screen is displayed.
- Review the Pre-Login message.
- Enter the administrator User Name and Password configured during initial setup.
- If the Acknowledge Pre-Login Message checkbox is displayed, click on it to acknowledge you have reviewed the pre-login information above. After initial login, you can enable and disable this checkbox via the Global Security Options. By default, this checkbox is configured as disabled.
Click Login. The main screen provides all WebUI functions, including tabbed options, menu tree, device name, and the last login date and time of the system.
Select Settings > System > Node-Level Settings.
CautionWhen you enter the Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
Unable to show "metadata-from": No such page "_space_variables"cannot connect to the Ribbon Application Management Platform.Use the following table to configure the Ribbon Application Management Platform (RAMP) panel.
Ribbon Application Management Platform ParametersParameter Description Connect to RAMP Configure this field to enable or disable the Ribbon Application Management Platform.
- No (default) - The Ribbon Application Management Platform is disabled.
- Yes - The Ribbon Application Management Platform is enabled.
- Yes with Redundancy.
Management Address Configure this field with the IP address or FQDN of the Ribbon Application Management Platform.
Note: This field applies only when the RAMP field is set to Yes.
Management ID Caution: When you enter the Ribbon Application Management Platform Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
Unable to show "metadata-from": No such page "_space_variables"cannot connect to the Ribbon Application Management Platform.Configure this field with the Management ID for the Ribbon Application Management Platform.
Note: This field applies only to the
Unable to show "metadata-from": No such page "_space_variables". The SBC 1000/2000 automatically sends the Management ID to the Ribbon Application Management Platform.Note: This field applies only when the Connect to RAMP field is set to Yes.
RAMP Connection The status of the SBC’s connection to the Ribbon Application Management Platform. This status may be one of the following:
- Down
- Up
Note: This field applies only when the Connect to RAMP field is set to Yes.
RAMP Tunnel Status The status of the HTTPS tunnel from the RAMP to the SBC. This status may be one of the following:
- Not Connected
- Up
Note: This field applies only when the RAMP field is set to Yes.
RAMP Online Licensing The status of the RAMP Licensing on the SBC. This status may be one of the following:
- None
- NWDL
- SBCaaS (Ribbon Connect)
Note: This field applies only to the
Unable to show "metadata-from": No such page "_space_variables".Note: This field applies only when the RAMP field is set to Yes.
HA Pair Name Enter the name of the Active and Standby instance to be paired.
The HA pair name allows RAMP to identify the Active and Standby SWe Edge HA instances as a single network entity.
- Click Apply.