You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

This section describes how to prepare for and physically install a 

Unable to show "metadata-from": No such page "_space_variables"
system.

Installing the SBC 2000 Chassis in a 4-Post Equipment Rack

The 

Unable to show "metadata-from": No such page "_space_variables"
chassis can be installed in a standard 19-inch, 4-post equipment racks. Mounting hardware is provided for racks with 24-inch and 30-inch depths.

Before installing the

Unable to show "metadata-from": No such page "_space_variables"
chassis in a 4-post equipment rack, you must first assemble and attach the 2 rear support brackets to the two rear rack posts.

To Assemble and Install the 
Unable to show "metadata-from": No such page "_space_variables"
Rear Support Brackets

  1. In the mounting hardware bag provided with the
    Unable to show "metadata-from": No such page "_space_variables"
    system, find the rear support brackets (2) and 9-inch extension arms (2).
  2. If you are installing the 
    Unable to show "metadata-from": No such page "_space_variables"
    system into a 30-inch depth rack, attach the extension arms to the support brackets.
  3. Attach the support brackets securely to the two rear posts of your equipment rack. Refer to the illustration below for visual details of the assembly:

    Assemble and Install Rear Support Brackets

     

The illustration above shows the rear bracket assembly for a rack with a 30-inch depth. For racks with a 24-inch depth, do not use the 9-inch extension arm and attach each support bracket directly to the rear rack posts.

To Install SBC 2000 in a 4-Post Equipment Rack

  1. Attach the 2 rack mounting ears securely to the front corners of the 
    Unable to show "metadata-from": No such page "_space_variables"
    chassis.
  2. Attach the 2 pan handle plates securely to the rear corners of the 
    Unable to show "metadata-from": No such page "_space_variables"
    chassis.
  3. Working with a partner, lift the 
    Unable to show "metadata-from": No such page "_space_variables"
    chassis and slide it into the equipment rack, making sure to seat each pan handle plate into the support brackets mounted on the rear support posts.
  4. Attach the 2 rack mounting ears securely to the front mounting posts of the equipment rack. Refer to the illustration below for visual details of the installation (click to enlarge).

    Install in 4-Post Equipment Rack

     

Do not block the air vents on either side of the 

Unable to show "metadata-from": No such page "_space_variables"
chassis. Both sides of the unit must clear to ensure proper cooling of the unit.

Installing the SBC 2000 Chassis in a 2-Post Equipment Rack

The

Unable to show "metadata-from": No such page "_space_variables"
chassis can be installed in a standard 19-inch, 2-post equipment racks by attaching the rack mounting ears to the middle attachment points on both sides of the chassis.

DO NOT mount the 

Unable to show "metadata-from": No such page "_space_variables"
chassis using only the rack ears attached to the front corners on a 2-post equipment rack. Mounting the chassis using only the front mount rack ears will not provide adequate mechanical support and can cause damage the
Unable to show "metadata-from": No such page "_space_variables"
chassis and other equipment in the rack.

To Install
Unable to show "metadata-from": No such page "_space_variables"
in a 2-Post Equipment Rack

  1. Attach the 2 rack mounting ears securely to the center mounting points on both sides of the 
    Unable to show "metadata-from": No such page "_space_variables"
    chassis.
  2. Attach the 2 rack mounting ears securely to the mounting posts of the equipment rack. Refer to the illustration below for visual details of the installation (click to enlarge).

    Install in 2-Post Equipment Rack

Installing Interface Cards

Under special circumstances for upgrades, a

Unable to show "metadata-from": No such page "_space_variables"
interface card may be delivered separately from the 
Unable to show "metadata-from": No such page "_space_variables"
chassis. The card must be installed before powering on the unit. For more information about 
Unable to show "metadata-from": No such page "_space_variables"
interface cards, see SBC 2000 Interface Cards. For more information about installing and removing interface cards, see Inserting and Removing Interface Cards.

You must power down the

Unable to show "metadata-from": No such page "_space_variables"
system before installing or removing Interface Cards. Hot swapping of Interface Cards is not supported.

Unknown macro: {multi-excerpt-include}

Installing Ground Wire, Power Cables and Connect Power

After you have completed the physical installation of the 

Unable to show "metadata-from": No such page "_space_variables"
chassis, connect the grounding wire and power cables

To Install the Grounding Wire and Power Cables

  1. Connect a grounding wire to the grounding bolt on the left side of the rear panel, in accordance with System Grounding Requirements.
  2. Connect power cords to the power supply and electrical sockets.

    If your equipment rack provides dual power circuits and your unit is equipped with a dual power supply, make sure to plug each power supply into a separate power circuit.

DO NOT INSTALL EITHER RIBBON or TELECOM CABLES. You must complete the Initial Configuration before connecting the 

Unable to show "metadata-from": No such page "_space_variables"
system to your network.

Installing the Cable Management Bracket

In order to provide cable strain relief for cables connected to 

Unable to show "metadata-from": No such page "_space_variables"
interface cards, a cable management bracket is provided.

To Install the Cable Management Bracket

  1. Place the cable management bracket on top of the pan handle plates.

    If you have installed the

    Unable to show "metadata-from": No such page "_space_variables"
    chassis in a 2-post configuration, you must install the pan handle plates on the rear corners of the chassis.

  2. Use the provided cable ties to secure the cable management bracket to the pan handle plates. Refer to the illustration below for visual details of the installation (click to enlarge).

    Install Cable Management Bracket

     

DO NOT INSTALL EITHER RIBBON or TELECOM CABLES. You must complete the Initial Configuration before connecting the 

Unable to show "metadata-from": No such page "_space_variables"
system to your network.

Next Steps

You are now ready to complete the initial configuration of the 

Unable to show "metadata-from": No such page "_space_variables"
system. Proceed to Running Initial Setup.

  • No labels