Use this object to configure H323 Signaling Port for this zone.
Each signaling port within an Address Context must use a unique IP address.
Each signaling port within an Address Context must use a unique IP address and port number combination.
The SBC 7000 system supports creating IP Interface Groups containing sets of IP interfaces that are not "processor friendly" (i.e. carried on physical Ethernet ports served by separate processors). However, restrictions exist regarding the usage of such Interface Groups.
(This ability does not apply to the SBC 5400, which has only two physical media ports. You may configure the IP interfaces from the two physical ports within the same IP Interface Groups without restrictions.)
For complete details, refer to Configuring IP Interface Groups and Interfaces.
On SBC main screen, go to Configuration > System Provisioning > Category: Base Provisioning > Signaling Ports > H323Sig Port. The H323Sig Port window is displayed.
Figure 1: Signaling Ports - H323Sig Port
The H323Sig Port can be checked for each Address Context or for each Zone or for all the Address Contexts and Zones created. Use the drop-down box to select the desired Address Context and Zone.
To edit any of the H323Sig Ports in the list, click the radio button next to the specific H323Sig Port name.
The Edit Selected H323Sig Port window is displayed below.
Figure 2: H323Sig Port Edit Window
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.
To create a new H323Sig Port, click New H323Sig Port tab on the H323Sig Port List panel.
Figure 3: H323Sig Port Fields
The Create New H323Sig Port window is displayed.
Figure 4: H323Sig Port Create Window
The following fields are displayed:
Table 1: H 323 Sig Port
Parameter | Description |
---|---|
| Specify the index value. |
| The name of the IP interface group used by this Signaling Port. |
| The 32-bit IP address used for H225 signaling. Specified in dotted decimal form (for example 128.127.50.224). Default is 0.0.0.0. |
| The logical port number of the UDP port to use for this connection. This defines the H.225 well known port. Must be 1-5000, default is 1720. |
| The 32-bit IP address used for H245 signaling. Specified in dotted decimal form (for example 128.127.50.224). Default is 0.0.0.0. This must equal ipaddress1 in the current implementation. |
| The operational state of the H323 signaling service:
|
| The administrative state of this H323 signaling port:
|
| The method by which active calls using this H323 signaling service are processed when MODE goes to out of service:
|
| The time (in minutes) to wait for active calls to finish in order to place the H323 signaling service in out of service MODE. Must be 0-1440, default is 0. |
| Differentiated Services Code Point value (0-63). |
To delete any of the created H323Sig Port, click the radio button next to the specific H323Sig Port which you want to delete.
Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision.