ASM Behavior on Ribbon SBC 1000/2000 Reboot Operation
Unable to show "metadata-from": No such page "_space_variables"
model, users with a built-in Working with the ASM: SBA, CCE and 3rd Party Applications may be impacted by this operation:

  • SBC 2000
  • If the ASM is running, rebooting the SBC will cause the ASM to also reboot.
  • If the ASM is shut down, rebooting the SBC will not restart the ASM.
  • To bring the ASM back into operation, you must physically power off and power back on the SBC.
  • SBC 1000 --- rebooting the SBC will reset the Ethernet port which could create an unreachable state for the ASM — this state lasts only a few seconds.


Rebooting the Ribbon 
Unable to show "metadata-from": No such page "_space_variables"

To reboot the 

Unable to show "metadata-from": No such page "_space_variables"
 system:

  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, under the System, click Reboot 

    Unable to show "metadata-from": No such page "_space_variables"


    Reboot

  3. Click OK. The following popup will be displayed to confirm the action:


    Confirm

  4. Click OK to reboot the system.
  5. The web interface will dispatch the following status message throughout the reboot cycle.


    Status Message

On average, the Ribbon SBC 1000/2000 system takes between 3 to 4 minutes to fully reboot and become reachable again through the web interface.