Resources | addressContext | zone | sipTrunkGroup | signaling | registration | insideExpiresMinimum

insideExpiresMinimum

This controls the initial expires value in a REGISTER relayed to a registrar. The max of this value and the value received from the IAD will be used.

NameValue
Type
NameinsideExpiresMinimum
PresenceO
Default3600
Base Typeuint32
constraintsMin-Value: 0
Max-Value: 100000