In this section:

Note

The following section is only applicable to the DSC 8000, the DSC SWe (on MA-RMS), the Signaling Platform 2000 (SP2000), and the virtual SP2000 (on MA-RMS).

You may have to configure the SS7 (T1/E1/J1) interfaces (ports) on the I/O card.

Note

If you are only provisioning M2PA, M2UA, or SUA links on your system, then you do not have to configure the SS7 (T1/E1/J1) interfaces (ports).

These interfaces may be set to

  • T1_D4 - configurable for 24 TDM channels with no cyclic redundancy (CRC) error check

  • T1_ESF - configurable for 24 TDM channels with cyclic redundancy (CRC) error check

  • E1 - configurable for 31 TDM channels with no CRC error check

  • E1_CRC4 - configurable for 31 TDM channels with CRC error check

  • J1 - configurable for 24 TDM channels at 1.5 Mbp/s with cyclic redundancy (CRC) error check
Caution

Make sure the local and remote SS7 port is set to the same T1/E1/J1 interface type. Otherwise, the system does not function as expected.

To configure port information

Click to read more...

To view port status

Click to read more...

To view Loopback Status

Click to read more...

To view gain and attenuation status

Click to read more...