TypeMAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.7

Description

This alarm indicates that an EMS/RAMP node ID has not been configured on the SBC.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_EMS_NODEID_NOT_CONFIGURED

Instance Fields

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusLicenseManagerGraceDaysLeft

Action

Check if the SBC has successfully registered with the EMS/RAMP and the performance data collection is enabled.

Impact

The SBC will not be able to register with the EMS/RAMP.

Note

If the SBC remains disconnected from the managing EMS/RAMP instance for an extended period of time, it will result in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact

Unable to show "metadata-from": No such page "_space_variables"
 Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.