You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.4

Description

This alarm indicates that the License Manager has rejected the registration request.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_SERVER_REGISTRATION_FAILED

Instance Fields

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusServerIpAddress
  • sonusLicenseManagerGraceDaysLeft

Action

Check the logs on the License Manager and correct the issues listed.

Impact

The SBC will not be able to register with the EMS/RAMP.

Note

If the SBC remains disconnected from the managing EMS/RAMP instance for an extended period of time, it will result in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact

Unable to show "metadata-from": No such page "_space_variables"
 Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.

Modified: for 10.1.2

Clearing

automatic; sonusCpLicenseManagerRegistrationSucceeded

  • No labels