DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.7
Alarm NamesonusCpLicenseManagerNoEmsNodeIdConfigured

Description

This trap indicates that an EMS nodeId has not been configured on the SBC.

Repetition

Repeats for each occurrence

Event Codes

EVENT_LICENSE_MANAGER_EMS_NODEID_NOT_CONFIGURED

Instance Fields

  • sonusAlarmNodeID,
  • sonusAlarmLevel,
  • sonusAlarmSequenceId,
  • sonusAlarmTime,
  • sonusAlarmDescription,
  • sonusLicenseManagerGraceDaysLeft

Action

Check the the SBC has been successfully registered with the EMS and the performance data collection has been enabled.

Impact

The SBC will not be able to register with the EMS. After the grace period expires, the SBC will not be able to process calls.
--ALARM_ONLY

Clearing

Manual