You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.3
Alarm NamesonusCpLicenseManagerCouldNotConnect

Description

This trap indicates that the connection to the License Manager failed.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_SERVER_CONNECT_ERROR

Instance Fields

sonusAlarmNodeID,
sonusAlarmLevel,
sonusAlarmSequenceId,
sonusAlarmTime,
sonusAlarmDescription,
sonusServerIpAddress,
sonusLicenseManagerGraceDaysLeft

Action

Please check the IP address in the message and check connectivity to that address.

Impact

The SBC will not be able to register with the EMS. After the grace period expires, the SBC will not be able to process calls.

Clearing

sonusCpLicenseManagerRegistrationSucceeded

  • No labels