In this section:
Configuring the Service Settings
This section outlines how to configure the service settings.
To Configure Service Settings
Choose Admin > Services Configuration.
Configure settings using the information in the following table as a guide.
Click Submit to make your changes take effect.
- A message indicates that service will be temporarily interrupted. Click OK to confirm.
Configuring SNMPv1
Configure SNMPv1 by itself or with SNMPv3. See Configuring SNMPv3.
To Configure SNMPv1
- Choose Admin > Services Configuration.
Select the Enable SNMPv1 checkbox.
In the SNMPv1 Read-Only Community field, enter the community string that the management station uses when accessing read-only objects from the system.
In the SNMPv1 Trap Agent IP Address field, enter a public IP address for the trap agent field that receives an SNMPv1 trap. If this value is not set, the agent uses the system WAN/Provider address.
NoteSNMPv1 Trap Agent IP Address is not the trap destination. Do not set this field unless you need to change the address contained within the body of the SNMP trap. See the Show Trap Destinations step to configure the trap destination IP address.
Select the Enable SNMP SETs checkbox to turn on SET messages that notify when the alarm threshold is exceeded.
In the SNMPv1 Read-Write Community field, enter a community string that the management station uses to access read-write objects from the system.
Click Show Trap Destinations to define the IPv4 address, SNMP version (1 or 2), and community string for one or more destinations that will receive SNMP traps.
In Add a Trap Destination, enter information in the fields provided:
- IP Address—IPv4 address. Specifying this address enables cold start, authentication and linkUp/linkDown SNMP traps.
- Version—SNMP version (1 or 2).
Community—Community string for one or more destinations that receive SNMP traps.
Click Add. Your entry appears in the Trap Destinations table.
To Delete a Trap Destination
To delete a Trap Destination, select checkboxes for the entries that you want to delete; click All to choose all entries or click None to clear your selections.
Click Delete.
A message indicates that service will be temporarily interrupted.
Click OK to confirm.
Click Hide Trap Destinations to remove the Trap Destinations window.
Proceed to the following:
- If you are configuring SNMPv3, see Configuring SNMPv3.
- If you are not configuring SNMPv3, see Configuring SNMP Common Settings.
Configuring SNMPv3
Configure SNMPv3 by itself or with SNMPv1. See Configuring SNMPv1.
To Configure SNMPv3
- Choose Admin> Services Configuration.
Select the Enable SNMPv3 checkbox.
In the SNMPv3 User Name field, enter the SNMPv3 username for SNMPv3 User-based Security Model (USM) and View-based Access Control Model (VACM) control.
In the SNMPv3 Password field, enter a password to authenticate the user encrypt the payload based on the SNMPv3 Security setting below. Minimum password length is 8 characters.
Choose an SNMPv3 security level from the SNMPv3 Security drop-down list. This is used for user authentication and for encrypting synchronous requests and synchronous and asynchronous traps. Default is None.
In the SNMPv3 Trap Context field, enter any string.
In SNMPv3 Trap Destination IP Address field, enter the IPv4 address to send SNMPv3 traps to. Specifying this address enables cold start, authentication, and linkUp/linkDown SNMPv3 traps.
In the SNMPv3 Engine ID (10-32 chars of hex pairs) field, enter a string that contains between 10 and 32 characters of hexadecimal pairs. If an Engine ID is not entered, the system generates one automatically. The ID may be needed by some trap clients that enforce a strict version of SNMPv3 authentication.
Proceed to Configuring SNMP Common Settings.
Configuring SNMP Common Settings
This section outlines how to configure the SNMP common settings.
To Configure the SNMP Common Settings
- Choose Admin > Services Configuration.
Scroll to SNMP Common Configuration.
In the System Location field, enter a comment string that can be used to indicate the location of the system. This field is blank by default, no value is set.
In the System Contact field, enter administrative contact information for the system. This field is blank by default, no value is set.
Leave the default SNMP port 161 in the Port field. The system monitors Port 161 to read and send SNMP data.
Proceed to Configuring Remote System Logging.
To Disable SNMP
- Choose Admin > Services Configuration.
- Clear the Enable SNMPv1 and Enable SNMPv3 checkboxes.
- Click Submit.
A message indicates that service will be temporarily interrupted. - Click OK to confirm.
To Delete an SNMP Trap Destination
- Choose Admin > Services Configuration.
- Click the wastebasket icon for the trap destination.
- Click Delete.
Configuring Remote System Logging
You must configure remote system logging to use MOS scoring. See Configuring Mean Opinion Score (MOS) Settings.
To Configure the Remote System Logging
- Choose Admin > Services Configuration.
Select Remote System Logging checkbox.
In the Remote Syslog Host field, enter the IP address of the system running the system log server. Multiple IPs can be entered by separating IPs with a space. You can also enter a fully qualified domain name (FQDN). The system sends to syslog port 514 by default.
Choose a logging level for the syslog service from the Syslog Filter drop-down list. The default priority is Debug.
Select the Enable REMOTE MOS Filter checkbox to enable remote syslog MOS filtering. This allows the EdgeMarc to send mean opinion score (MOS) filtered syslog records to an individually defined syslog server.
In the Remote MOS Filtered Syslog Hosts field, enter the IP address of the system running the system log server. Enter multiple IPs by separating them with a space. The system sends to the default syslog port 514. The port cannot be changed.
Choose a MOS filter facility type from the MOS filter facility drop-down list. This filters MOS records from the syslogs that are sent to the remote MOS filtered syslog hosts. Default is local2.
Configuring an EdgeView Group Name
The EdgeView Group Name field allows you to input the EdgeView Service Control Center (EdgeView SCC) group name within which the EdgeMarc will reside. This overrides any entry of the EdgeMarc MAC address in the EdgeView database.
To Configure an EdgeView Group Name
- Choose Admin > Services.
- Scroll to the EdgeView Group Name field.
- Enter an EdgeView group name and click Submit.
Managing EMPath Management Server
A user can point the EdgeMarc VOS to an EdgeView version 15 or higher using this field.
To Manage the EMPath Management Server
- Choose Admin > Services Configuration.
- Scroll to EMPath Management Server.
In the EMPath Management Server field, enter a valid IPv4, IPv6 or FQDN address for connecting to an EdgeView version 15 or higher.
Managing Source Address Settings
This feature is used only for specific environments and only when there are two distinct WAN connections; WAN management only occurs on one of the two WAN connections. Contact Ribbon customer support for more information (refer to Contact and Support).
To Manage the Source Address Settings
- Choose Admin > Services Configuration.
- Scroll to Management Source Address.
In the Management Source Address field, enter the system public WAN IPv4 or IPv6 source address to manage data that originates from the system. This field is generally not changed. Default is the system public WAN IP.
Managing Hostname Settings
This section outlines how to manage the hostname settings.
To Manage the Hostname Settings
- Choose Admin > Services Configuration.
- Scroll to hostname settings. The current hostname is displayed in the Current Hostname field.
Enter a new hostname for the system in the Set Hostname field. The system hostname is limited to 50 characters and must observe the following format: “ABC_company_4500” or “ABC-company-4500.”
Once set, this name becomes the Hostname on the Administration home page.
Configuring Mean Opinion Score (MOS) Settings
You must configure remote system logging to use MOS scoring. See Configuring Remote System Logging.
To Configure the MOS Settings
- Choose Admin > Services Configuration.
Scroll to Enable MOS Scoring.
Select the Enable MOS Scoring checkbox. MOS scoring is enabled by default. Disabling MOS scoring improves system performance.
In the Set MOS Threshold field, enter the minimum MOS threshold allowed for the system. By default, the value is 2.5. MOS values set below this cause system messages to be sent to the system log. The Current MOS Threshold field shows the current MOS threshold for this system.
Click Submit. The new value appears in Current MOS Threshold.
To save all settings on the page, click Submit All.
Configuring System Monitor
This section outlines how to configure the system monitor.
To Configure the System Monitor
- Choose Admin > Services Configuration.
Scroll to Enable System Monitor.
- Select the Enable System Monitor checkbox to prepare the system to gather Poll Cycle Length, /var space usage threshold, /etc/config space usage threshold, RAM usage threshold, CPU usage (user) threshold, CPU usage (system) threshold, and CPU usage (overall) threshold.
System Monitor is disabled by default.
Configuring Analytics
This section outlines how to configure the analytics.
To Configure the Analytics
- Choose Admin > Services Configuration.
Scroll to Enable Analytics.
Select the Enable Analytics checkbox to prepare the system to gather SIP, Memory, and CPU utilization statistics. Statistics gathering is initiated after the first SNMP GET request is received by the system. Analytics is enabled by default.
Enter a value in the Set Analytics Timeout field to set the timeout, in minutes, from the last SNMP GET request to disable statistics collection. Timeout values range from 2 to 1666666. By default, the value is 60 minutes.