Parameters
Parameter Name | Required | Service Affecting | Data Type | Default Value | Possible Values | Description |
---|
digitalRelayState | No | Yes | Enum | 0 | Possible values: - 0 - rcsOnline
- 1 - rcsPassThru
- 2 - rcsPowerdownPassThru
|
Configures the digital relay state
- rcsOnline - each DS1 pair of ports are connected to the unit and capable of originating and terminating PSTN calls.
- rcsPassThru - each DS1 part of ports are in pass through and not connected to the unit.
- rcsPowerdownPassThru - each pair of ports is cross-connected when the unit's power is lost or powered off.
|
---|
analogSysRelay | No | Yes | Enum | 0 | Possible values: - 0 - rcsOnline
- 1 - rcsPassThru
- 2 - rcsPowerdownPassThru
|
Configures the digital relay state
- rcsOnline - each Relay FXS and FXO port pairs are connected to the unit and capable of originating and terminating PSTN calls.
- rcsPassThru - each Relay FXS and FXO port pairs are in pass through and not connected to the unit.
|
---|
Helpful Tip
The POST can contain either only the attributes that are being updated, or the full set of attributes for the resource