You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.63

Description

This alarm is raised when TCP connection to a particular monitoring server is not established after three failed attempts (IPv6).

Repetition

Yes

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescriptin
  • sonusMonIpAddressV6
  • sonusMonPortNum

Instance Fields

  • sonusMonIpAddressV6
  • sonusMonPortNum

Action

Reestablish the TCP connection.

You must manually disable or enablethe the monitoring profile state after taking correction actions.

Impact

The SBC cannot stream SIP PDUs to the monitoring server since the TCP connection is not established.

Clearing

Manual


  • No labels