Type: MINOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.50
DescriptionThis alarm indicates that registration is rejected due to the unavailability of the ports.
RepetitionYes.Repeats every time the registration fails due to unavailability of the ports
Event CodesSIPSG_PORT_RANGE_REGISTRATION_FAILED
Instance FieldssonusAddressContextName, sonusZoneName, sonusTrunkgroupName
ActionIncrease the range of configured ports within the media port range under system level or IPTG, if configured,
ImpactRegistration failed. Any further registrations on this SipTrunkgroup does not succeed.
ClearingManual

 