Description

This alarm indicates that the recording request is rejected due to the unavailability of the recording server.

Repetition

None

Event Codes

SIPSG_RECORDING_FAILED_V6

Instance Fields

  • sonusRecorderIpAddress – The IPV6 of recorder which is unavailable
  • sonusRecorderPortNum – The port of recorder which is unavailable
  • sonusRecCallGCID – The GCID of the call being recorded
  • sonusRecorderTrunkName – The trunk group name where recorder is configured
  • sonusRecordingCallLeg – The leg, ingress or egress, being recorded

Action

None

Impact

Recording failed for IPv6 recorder

Clearing

Manual