You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
Version 1
Current »
Use this parameter to specify how to treat call forwarding history information.
To View and Edit History Information
On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Ip Signaling Profile > Egress Ip Attributes > Sip Headers And Parameters > Call Forwarding > History Information. The History Information window is displayed.
DEFAULT_H323
On the History Information window, choose the Ip Signaling Profile as DEFAULT_H323 to view the History Information for H323 Trunk Group.
Trunk Provisioning - Egress Ip Attributes H323 History Information
There are no History Information parameters for DEFAULT_H323 type of Egress Ip Attributes.
DEFAULT_SIP
On the History Information window, choose the Ip Signaling Profile as DEFAULT_SIP to view the History Information for SIP Trunk Group.
Trunk Provisioning - Egress Ip Attributes SIP History Information
The following fields are displayed:
Egress Ip Attributes Call Forwarding
Parameter | Description |
---|
Include History information | Enable this flag to include History-Info in INVITE egress message. |
Cause Parameters In RFC4458 | Enable this flag to include the History-Info cause value in egress message as per RFC 4458 recommendation. When the flag is enabled, the output is similar to the following example:
History-Info: < sip:1234567890@P1.interwork.com?Privacy=none>;index=1, <sip: last_diverting_target;cause=408>;index=1.1 |
Reason With Cause Value As Per RFC4244 | Enable this flag to include History-Info cause value with Reason Header as per RFC 4244 recommendation. When the flag is enabled, the output is similar to the following example:
History-Info: <sip:1234567890@P1.interwork.com?Privacy=none>;index=1, <sip: last_diverting_target?Reason=SIP%3Bcause%3D408>;index=1.1 |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.