You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 4
Next »
This object displays call CDR configuration.
Records are always written to the local disk.
On SBC main screen, go to Administration > Accounting and Logs > Admin. The Cdr Admin window is displayed.
Accounting and Logs - Edit Cdr Admin Window
The fields displayed are:
Parameter | Description |
---|
Generation Mode
| The type of calls for which accounting records should be logged on this Unable to show "metadata-from": No such page "_space_variables" : |
Intermediate Acct State
| Specifies whether Intermediate Accounting is Enabled or Disabled for the Node. Options are: enabled disabled (default)
|
Intermediate Acct Interval
| This configures the intermediate accounting interval in seconds.
This object is only applicable when sonusAcctIntAcctMode is set to interval(1).
|
Second Stage Inherit First Stage
| Enable flag to allow second stage accounting records for two stage calls to inherit fields from the first stage call. Options are: |
Populate Non-ported LNP Numbers
| Enable flag to populate the Called Number Before Translation field in the accounting record for a number for which an LNP lookup was performed and lookup indicated that number has not been ported. Options are: |
Intermediate Acct Mode
| Specifies the method by which intermediate records are generated. Options are: interval (default)—Generate an intermediate record for each intermediateAcctInterval seconds throughout the call.telcordia —Generate an intermediate record whenever the call exceeds the configured intermediateLongDurThreshold value (in hours) and the intermediateLongDurGenTime (of day) is reached.
|
Intermediate Long Dur Gen Time
| Specifies Octet string that identifies the GMT time to generate Telcordia Long Duration accounting records. The format is 00:00:00.0 where each field is:
field octets contents range
----- ------- ------------ -----
1 1 hour 0..23
2 2 minutes 0..59
3 3 seconds 0..60 (use 60 for leap-second)
4 4 deci-seconds 0..9
|
Start Acct State
| Specifies whether Start Accounting is Enabled or Disabled for the Node. Options are: |
Event Acct State | Enable flag to generate EVENT records for OOD SUBSCRIBE, REFER, NOTIFY, REGISTER, OPTIONS, MESSAGE and PUBLISH event records. CDRs are logged when OPTIONS is relayed to the egress side. Disabled (default)Enabled
|
Event Acct PSX Info State | Log event records containing PSX information, such as PSX Congestion level, PSX Processing Time, Policy Response Call Type, PSX Billing Info, Route Label. Disabled (default)Enabled
|
Intermediate Trap State
| Specifies whether a trap will be generated whenever an INTERMEDIATE record is generated. Options are: |
Populate Remote GSX Info State
| Specifies whether a destination Unable to show "metadata-from": No such page "_space_variables" propagates its billing data to originating GSX for GW-GW calls.Options are: |
Early Attempt State
| Specifies whether or not to generate early ATTEMPT records. An early ATTEMPT record is associated with an early call disconnect, before the request is sent. Options are: enabled (default) - Do not generate early ATTEMPT records.disabled - Generate early ATTEMPT records.
|
Intermediate Long Dur Threshold
| Specifies the Accounting INTERMEDIATE Records Duration (in hours). Must be 1-24; default is 24. This parameter is only applicable when intermediate records mode is set to telcordia. The INTERMEDIATE record is generated for each call whose duration exceeds this threshold on long duration generation time. |
Send Egress CDR Info on Receipt
| Specifies whether or not to send the egress CDR information immediately after receiving and processing it. Options are: |
Populate IP TG Far End Switch Type
| Specifies whether or not to use Ingress Far End Switch Type passed down from PSX IP TG for SIP ingress calls. Options are: |
Max Record Sequence Num
| Specifies the maximum length of the Record Sequence Number field in the CDR. Options are: uint16 (default)—16-bit record sequence number 0 to 65535.uint32 —32-bit record sequence number 0 to 4294967295.
|