Use the licenseRequired
table to specify the feature licenses that the
Unable to show "metadata-from": No such page "_space_variables"
will request from the Site License Server (SLS) when the
Unable to show "metadata-from": No such page "_space_variables"
is operating in a network wide license deployment with the
licenseMode
configured as "network".
Services enabled by a counted license can be configured with a minCount
and a maxCount
value. When these values are equal, the
Unable to show "metadata-from": No such page "_space_variables"
requests and retains that number of licenses at the
Unable to show "metadata-from": No such page "_space_variables"
irrespective of demand for the license. When the values for these fields are different, the
Unable to show "metadata-from": No such page "_space_variables"
maintains the number of licenses configured in
minCount
irrespective of demand, and it will never request more licenses than the configured
maxCount
value.
Command Syntax
% set system licenseRequired <feature name>
maxCount <2-1000000, or "unlimited">
minCount <1-256000>
Command Parameters
License Required Parameters
Parameter | Length/Range | Description |
---|
licensesRequired | N/A | <feature name> – The licensing feature name.
|
minCount | 1–256000 | Use this parameter to specify the minimum number of licenses the Unable to show "metadata-from": No such page "_space_variables" will request from the SLS to retain at the Unable to show "metadata-from": No such page "_space_variables" (regardless of demand) when the associated license is first configured. (Default = 1)When the minCount is set to the default value of "1", one license is requested from the SLS and retained at the Unable to show "metadata-from": No such page "_space_variables" to verify the availability of the feature license. When minCount is configured for a service that is already active, the Unable to show "metadata-from": No such page "_space_variables" immediately requests the additional licenses required to reach the configured minimum count. If the licenses that are present at the Unable to show "metadata-from": No such page "_space_variables" have already surpassed the configured minimum, the Unable to show "metadata-from": No such page "_space_variables" does not make any additional license requests.If a configured minimum count is not the SLS, the alarm sonusSbxMinimumLicenseCountThresholdNotReached is raised to indicate the Unable to show "metadata-from": No such page "_space_variables" is running below the configured minimum count for the associated license. |
maxCount | 2–1000000, or "unlimited" | Use this parameter to specify the maximum number of licenses the Unable to show "metadata-from": No such page "_space_variables" can request from the SLS. (Default = 'unlimited')If the system is utilizing licenses and the maxCount is reconfigured to a value less than the licenses already in use, the Unable to show "metadata-from": No such page "_space_variables" does not reject existing sessions using the license, and throttles new attempts requiring the license to the newly configured limit. If the Unable to show "metadata-from": No such page "_space_variables" is operating above the configured threshold, the alarm sonusSbxMaximumLicenseCountThresholdExceeded is raised. This condition restricts further use of the licensed feature until the number of licenses at the Unable to show "metadata-from": No such page "_space_variables" drop below the configured maximum. |
Command Example
set system licenseRequired SBC-PSX-RTU minCount 10 maxCount 100
commit
show details system licenseRequired
licenseRequired SBC-PSX-RTU {
minCount 10;
maxCount 100;
}