You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

In this section:

Sonus-provided SFP/SFP+ modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

1 Gb SFP Characteristics

The 

Unable to show "metadata-from": No such page "_space_variables"
supports the following Small Form-factor Pluggable (SFP/SFP+) transceivers. The SFPs (SFP/SFP+) are Customer Replaceable Units (CRU).

The following SFP transceivers are compatible with 

Unable to show "metadata-from": No such page "_space_variables"
Management ports:

1Gb SFP Parts

Transceiver TypeProduct CodeSFP TypeManufacturers  Part NumberWavelength  (nm)Tx Power (dBM)Rx Power (dBM)

Description
Multi-mode fiber

SBC-SFPMM-1G

 

1G Ethernet
MM

AVAGO TECHNOLOGIES AFBR‐5715PZSN1, 
BROADCOM AFBR‐5715PZ‐SN1, 
FINISAR FTLF8519P2BNL‐SS, 
FINISAR  FTLF8519P3BNL‐SS

850-9.5 (Min)-3 (Max)-17 (Min)0 (Max)GIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
Single-mode fiber

 SBC-SFPSM-1G

 

1G Ethernet  SMAVAGO TECHNOLOGIES AFCT‐5715PZSN1, 
BROADCOM AFCT‐5715PZSN1,
FINISAR FTLF1318P2BTL‐SS, 
FINISAR FTLF1318P3BTL‐SS
1310-9.5 (Min)-3 (Max)-19 (Min)-3 (Max)

GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI

CopperSBC-SFPCOPPER-1G1G Ethernet CopperAVAGO TECHNOLOGIES ABCU-5740RZ-SN1,
BROADCOM ABCU-5740RZ-SN1,
FINISAR FCLF8521P2BTL-SS
NANANANANAGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)

Note

These numbers are taken from Vendor Datasheets as well as IEEE 802.3ae for the 1G parts.

 

10 Gb SFP Characteristics

The following SFP+ transceivers are compatible with 

Unable to show "metadata-from": No such page "_space_variables"
Media and HA ports:

10Gb SFP Parts

Transceiver TypeProduct CodeSFP TypeManufacturers  Part NumberWavelength  (nm)Tx Power (dBM)Rx Power (dBM)

Description
Multi-mode fiber

SBC‐SFPMM‐10G

10G Ethernet
MM

AVAGO TECHNOLOGIES AFBR‐709SMZSN1, 
BROADCOM AFBR‐709SMZ‐SN1, 
FINISAR FTLX8571D3BCL‐SS,
FINISARFTLX8574D3BCL‐SS

850-7.9 (Min)-1 (Max)-11.1 (Min)0.5 (Max)

10.3 GB/S, MULTIMODE, FIBER OPTIC XCVR, LC, SFP, 300M 850NM, DMI GIG-E, SINGLE MODE,
FIBER OPTIC TRANSCEIVER MODULE

Single-mode fiber

SBC‐SFPSM‐10G

 

10G Ethernet  SMAVAGO TECHNOLOGIES AFCT‐709SMZSN1, 
AVAGO TECHNOLOGIES AFCT739SMZ‐SN1, 
BROADCOM AFCT‐709SMZSN1, 
BROADCOM AFCT‐739SMZ‐SN1, 
FINISAR FTLX1471D3BCL‐SS
1310-8.2 (Min)0.5 (Max)-12.6 (Min)0.5 (Max)10.3 GB/S, SINGLE MODE, FIBER OPTIC XCVR, LC, SFP, 10KM 1310NM, DM

Note

These numbers are taken from Vendor Datasheets as well as IEEE 802.3ae for the 10G parts.

 

Parts and Tools Required

The following items are needed to install/replace a SFP/SFP+ device:

  • Electrostatic discharge (ESD) strap
  • Replacement SFP/SFP+ transceivers.

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. See Connecting Electrostatic Discharge Wrist Strap on SBC 7000 to install it.

Replacing the SFP/SFP+

To replace the SFP/SFP+:

  1. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis. Follow the instructions in the section Connecting Electrostatic Discharge Wrist Strap on SBC 7000.
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Media 0-4) and HA ports (HA 0-1).
  3. Disengage the SFP/SFP+ transceiver from

    Unable to show "metadata-from": No such page "_space_variables"
    . The method used to disengage the SFP/SFP+ transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards.

  4. Insert the Sonus-approved SFP/SFP+ transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality by using the application.

CRU Storage

All 

Unable to show "metadata-from": No such page "_space_variables"
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

The ESD Susceptibility symbol warns of the presence of Ribbon devices susceptible to electrostatic discharge. Do not handle equipment without wearing a properly grounded ESD wrist strap.

  • No labels