In this section:
It is important to select the correct firmware file for the existing platform type. The upgrade fails if the platform type mismatches with the selected firmware upgrade file. For example: For SBC 7000 Series platform, the firmware upgrade file should be firmware-7x00-V0x.xx.00-R000.img
file.
The following details helps to choose the correct firmware file for an upgrade:
Platform Type | Firmware file |
---|---|
SBC 5000 Series (5100, 5110, 5200, 5210) | Upgrade from 2.x to 3.x version:
Upgrade from 3.x to 3.y version:
|
SBC 5400 | Upgrade from any version to latest version:
|
SBC 7000 Series | Upgrade from any version to latest version:
|
The SBC 5400 and the SBC 7000 Series BMC firmware is upgraded using the normal upgrade method (using the ".img
" file). The normal upgrade method allows you to directly upgrade from any version to the latest BMC version. Refer to Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series to know the procedure.
The two BMC Firmware upgrade paths are listed below. Identify the file type to use for an upgrade:
BMC upgrade from 2.x to 3.x: Use the ".rom
" file.
For example: To upgrade from BMC 02.16.00 to 03.00.00, use "bmc5X00_v3.0.0-R0.rom
" file.
The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the standard method first and then perform an upgrade to 3.x version using a ".rom
" file.
.img
" file. firmware-5XX0-V03.11.00-R000.img
" file.The following procedure describes how to upgrade the BMC firmware from 2.x to 3.x versions (02.16.00 to 03.00.00) using the ".rom
" file.
Download the required BMC firmware version from Salesforce prior to continuing. Refer to Downloading the Software from Salesforce for details.
Use this procedure to upgrade BMC firmware from 02.16.00 to 03.00.00 version.
Log on to the SBC BMC using the following credentials:
Username: <username>
Password: <default password>
Click Remote Control. The Remote Control window is displayed.
Click Power Control in the Options panel. The Power Control and Status window is displayed.
Choose Power Off Server - Orderly Shutdown option.
Click Perform Action to initiate the shutdown process.
Click Maintenance tab. The Maintenance window is displayed.
Click Enter Update Mode. A message appears seeking your permission to proceed.
Click OK to proceed. The BMC is now in the Upgrade Mode.
Browse and select the firmware file to upload. The firmware file to upgrade from 2.x to 3.x version should be a ".rom
" file. For example: bmc5X00_v3.0.0-R0.rom
file.
Click Upload Firmware. The BMC validates the selected file.
Once the verification is complete, a message is displayed stating the result of the verification.
Click OK to proceed. The existing and the new BMC versions are displayed for validation.
The BMC fails to upgrade if:
Click Start Upgrade to initiate the upgrade process.
A confirmation message appears seeking your permission to proceed with the upgrade.
Once the upgrade process starts, do not close the screen.
Click OK to proceed. The BMC starts the firmware upgrade process.
Access the same BMC IP address to reach the BMC login window. Observe the changes in the login window.
In the new BMC version (03.00.00), the login window has some additional browser settings displayed.
Log on to the SBC BMC using the following credentials:
Username: <username>
Password: <default password>
The following procedure describes how to upgrade the BMC firmware from 3.x to 3.x versions (for example; from version 03.10.00 to version 03.11.00) using the Disc Image File.
Log on to the SBC BMC using the following credentials:
Username: <username>
Password: <default password>
The BMC main screen is displayed.
Click Firmware Update.
Click Browse, and from the Open dialog browse to and select firmware-5XX0-V<release>.img firmware image. Refer to the Warning at the start of this page to make sure you have chosen the correct type of file for an upgrade. To determine the exact firmware version, refer to SBC Release Information for guidance.
The chosen file displays next to the Browse button.
Click Upload.
The firmware image is approximately 17MB (for SBC 5000 Series) and 24MB (for SBC 5400 and SBC 7000 Series) and takes few minutes to upload based on the network.
The BMC fails to upgrade if:
The selected file is verified and the uploading process starts.
Once the file verification is complete, BMC seeks your permission to proceed further with the upgrade. Click Confirm to proceed.
This is a service affecting procedure and will power off the host side of SBC.
Once the upgrade process starts, do not close the screen.
Click OK to complete the process.The BMC automatically restarts at this point.
Close the existing browser window.
Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.
Log on to the BMC using the default credentials:
Username: <username>
Password: <default password>
The SBC BMC compels you to change the password after a successful upgrade.
This change is applicable only when the BMC is upgrade to version 03.13.00 and later versions.
Click OK to proceed. The User Management window is displayed.
You have an option to cancel the action. If cancelled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on you next login to BMC. This reminder continues till the password is changed. To know more about how to successfully change the SBC BMC password, refer to Changing the BMC Password.