You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
Version 1
Next »
This section specifies the Redirect parameters for Egress Ip Attributes.
To View and Edit Redirect
On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Ip Signaling Profile > Egress Ip Attributes > Redirect. The Redirect window is displayed.
DEFAULT_H323
On the Redirect window, choose the Ip Signaling Profile as DEFAULT_H323 to view the Redirect parameters for H323 Trunk Group.
Trunk Provisioning - Egress Ip Attributes H323 Redirect
There are no Redirect parameters for DEFAULT_H323 type of Egress Ip Attributes.
DEFAULT_SIP
On the Redirect window, choose the Ip Signaling Profile as DEFAULT_SIP to view the Redirect for SIP Trunk Group.
Trunk Provisioning - Egress Ip Attributes SIP Redirect
The following fields are displayed:
Egress Ip Attributes SIP Redirect Parameters
Parameter | Description |
---|
Mode | Use this object to control SIP redirection: Accept Redirection – (default) Multiple redirection are allowed.Allow Single Redirect Attempt – Only a single Redirect is allowed per route. Additional Redirects cause crankback to be performed.Reject Redirection – If a Redirect is received, crank back is performed.
|
Contact Handling | Select one of the following to control processing of contacts received in SIP Redirects: Merge Received Contacts – Contacts received in Redirects are ordered by q-value and inserted at the head of the list of untried contacts.Purge Existing Contacts – Contacts received in Redirects are ordered by q-value and replace untried contacts.
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.