Scenario
Establish configuration to prevent a subscriber from dialing international numbers
The initial configuration is performed with the following background information:
- System has been assembled and software installed at the factory.
- System is cabled together (HA) and into the customer's network.
The
Unable to show "metadata-from": No such page "_space_variables"
defines the default instances for most profile objects.
The initial installation specifies the values for the following required entities:
- Administrator account
- Default system name
- Two physical servers, or computing elements (CEs), with default names
- Hardware link interfaces (ports) per server, with default names (pkt0 - pkt3)
- Redundancy configuration
- Management and HA interfaces IP address, net masks
- Management Interfaces default Routes
The following procedure assumes that the management IP interfaces have already been configured as part of the
Unable to show "metadata-from": No such page "_space_variables"
setup.
Workflow
- Create a new Subscriber John Smith. Set DN to John Smith's telephone number.
- Create a new Class Of Service (COS) "Block International Calls".
- Set Call Blocking Service: enabled.
- Set Call Block Entry: 011* (international dial string)
- Associate Subscriber "John Smith" with COS created above. Set John Smith's COS reference to "Block International Calls".