You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

In this section:

This section provides the safety and regulatory information for 

Unable to show "metadata-from": No such page "_space_variables"
platforms.

Compliance Model Number

For the purpose of regulatory compliance certifications and identification, the 

Unable to show "metadata-from": No such page "_space_variables"
systems are assigned Compliance Model Numbers:

  • SBC 5200 and SBC 5100 are assigned Compliance Model Number SONW-1201.
  • SBC 5210 and SBC 5110 are assigned Compliance Model Number SONW-1301

The compliance model number is available on the product label along with the required approval markings and information. Refer to the compliance model number while requesting for certification information for the product.

Safety Notices and Warnings

Read and observe all Notes, Cautions, and Warnings before beginning the SBC 5000 system hardware installation.

Caution

1) Connect the chassis to protective earth ground before connecting the power to the unit.

2) Disconnect all the input power sources to disconnect power from the unit.

Error rendering macro 'excerpt-include'

No link could be created for 'Introduction'.

Safety Standards

The following table provides various standards for different 

Unable to show "metadata-from": No such page "_space_variables"
hardware platform:

 PlatformSafety StandardsEMC and Immunity StandardsEnvironmental Standards
5100/5200

SBC 5100/5200 comply with the following standards, and is listed with TUV SUD America:

  • IEC/EN60950-1: 2005 2nd Ed + A1:2009
  • EN 60950-1:2006/A11:2009/A1:2010
  • UL 60950-1:2007, CAN CSA-22.2 No. 60950-1:2007

SBC 5100/5200 systems comply with the following EMC and Immunity standards:

  • 47 CFR 15B Class A
  • ICES-003 Class A
  • EN55022 Class A
  • VCCI Class A
  • AS/NZ 3548 Class A
  • EN 300-386
  • EN55024
  • IEC 61000-4-2
  • IEC 61000-4-3
  • IEC 61000-4-4
  • IEC 61000-4-5
  • IEC 61000-4-6
  • IEC 61000-4-8
  • IEC 61000-4-1

EN 300-019

5110/5210

SBC 5110/5210 comply with the following standards, and is listed with TUV SUD America:

  • IEC 60950-1/A1:2009
  • EN 60950-1/A12:2011
  • UL 60950-1r:2011-2, CAN/CSA C22.2 No. 60950-1/A:2011
  • "CLASS 1 LASER PRODUCT", CLASSE 1

SBC 5110/5210 systems comply with the following EMC and Immunity standards:

  • 47 CFR 15B Class A
  • ICES-003 Class A
  • EN55022 Class A
  • VCCI Class A
  • AS/NZ 3548 Class A
  • EN 300-386
  • EN55024
  • EN61000-3-2:2006/A1:2009/A2:2009
  • EN61000-3-3:2008

EN 300-019

Compliance Statements (Only for 5110 and 5210)

FCC EMC Statement (Class A)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

Canada ICES - 003 EMC Statement (Class A)

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

European Union EN 55022 EMC Statement (Class A)

Warning

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Taiwan EMC Statement (Class A)

Brazil EMC Statement (Class A)

Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra    interferência prejudicial, mesmo de estações do mesmo tipo, e não  pode causar interferência  a  sistemas operando em caráter  primário.

Japan VCCI Notice



This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may occur, in which case, the user may be required to take corrective actions.

China CCC Compliance

This is a Class A product based on the standard of the China Compulsory Certificate (CCC).

NEBS Level 3 Compliance

The SBC 5000 systems comply with Telcordia NEBS Level 3 requirements per SR-3580, including the appropriate sections of GR-63-CORE (Network Equipment-Building System Requirements: Physical Protection) and GR-1089- CORE (Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications Equipment).