You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 2
Next »
EVENT accounting records for 5.0.x release
Field Name | Field Number | Description |
---|
Record Type | 1 | EVENT |
Gateway Name | 2 | Max Length = 23 |
Record Sequence Number | 3 | Max Length = 10 |
Sip Method | 4 | Max Length = 15 |
Sip Txn Status | 5 | "Successful transaction" -1 "End of SUBSCRIBE dialog" -2 "End of REGISTER dialog" - 3. "3xx Request failure" 3xx "4xx Request failure" 4xx " 5xx Request failure" 5xx " 6xx Request failure" 6xx "Unspecified error" 1 “Internal Error” 2 “Registration or Subscribe Timer Expiry” 3 |
Event Package | 6 | Received Event Header, Max Length = 25 |
SIP Request Rxd Time in Ticks | 7 | Max Length 10 |
Node Time Zone | 8 | Max Length 23 |
SIP Request Start Time (Date) | 9 | Max Length 10 |
SIP Request Start Time (Time) | 10 | Max Length 10 |
Ingress Trunk Group Name | 11 | Max Length 23 |
Ingress Local Gateway Signaling IP Address | 12 | Max Length 39 |
Ingress Remote Gateway Signaling IP Address | 13 | Max Length 39 |
Service Provider | 14 | Max Length 23 |
CarrierCode | 15 | Max Length 5 |
Egress Trunk Group Name | 16 | Max Length 23 |
Egress Local Gateway Signaling IP Address | 17 | Max Length 39 |
Egress Remote Gateway Signaling IP Address | 18 | Max Length 39 |
Time Elapsed from Receipt of SIP Message to Policy Server Response | 19 | Max Length 10 |
Time Elapsed from Receipt of Sip Message to Last Routing Attempt | 20 | Max Length 10 |
Time Elapsed from Receipt of Sip Request Message to SIP Response Rxd | 21 | Max Length 10 |
Registered User | 22 | Max Length 1, This field is logged when we receive OOD Requests from Registered user. |
Challenged Request Received | 23 | Max Length 1 |
Duration of SIP Registration/Subscription Context | 24 | Max Length 10 |
Service Disconnect Reason | 25 | Max Length 3, CPC Cause Code |
Ingress Signaling Information | 26 | Max length of 2200 Bytes is logged. For detailed information, refer to EVENT Accounting Records for Ingress/Egress Fields. |
Egress Signaling Information | 27 | Max length of 2200 Bytes is logged. Egress Signaling info based on response. For detailed information, refer to EVENT Accounting Records for Ingress/Egress Fields. |
PSX Routing Info | 28 | For detailed information, refer to PSX Routing Information in EVENT Code. |
UE Roaming Status | 29 | Max length 1 (decimal) |
Emergency Indicator | 30 | Max length 1 (Boolean) |
In this section: