This section describes the upgrading procedure of M-SBC in N:1 Redundancy Group.
Perform the following activities prior to upgrading the M-SBC in an RG.
Download the required .QCOW2
file from the Salesforce Customer Portal.
To upload the .QCOW2
file to the OpenStack, navigate to Project > Compute > Images. For more information, refer to Creating Glance Image.
In an M-SBC Redundancy Group (RG), ensure all the five instances (4:1), configurator instance, and EMS is up and running.
To check the instances, navigate to Project > Compute > Instances. The Instances window is displayed. The Instances window displays the status of the current image.
To identify the standby instance, perform the following steps:
Execute the the command getUserData
and check the value of the parameter CERole
Repeat the above steps for each instance until you identify the standby instance.
Perform the following steps to upgrade.
To select an image:
On the OpenStack, navigate to Project > Compute > Instances. The Instances window is displayed.
From the drop-down list, corresponding to the standby instance, select the option Rebuild Instance.