This section describes
Unable to show "metadata-from": No such page "_space_variables"
hardware and software requirements and recommendations.
To install and configure
Unable to show "metadata-from": No such page "_space_variables"
, make sure the Virtual Machine (VM) host meets the following recommended hardware, server platform and software requirements.
Warning
The recommended hardware and software settings are intended to ensure optimum
Unable to show "metadata-from": No such page "_space_variables"
stability and performance. If the recommended settings are not used,
Unable to show "metadata-from": No such page "_space_variables"
system may not behave as expected.
SBC SWe for KVM Hypervisor – Server Hardware Requirements
The following table lists the server hardware requirements.
KVM Hypervisor Server Hardware Requirements
Configuration | Requirement |
---|
Processor | Intel Xeon processors (Nehalem micro-architecture or above) with 6 cores and above (processors should support hyper threading).
|
RAM | Minimum 24 GB |
Hard Disk | Minimum 500 GB |
Network Interface Cards (NICs) | Minimum 4 NICs.
|
Ports | Number of ports allowed: - 1 Management port
- 1 HA port
- 2 Media ports
|
Warning
The
Unable to show "metadata-from": No such page "_space_variables"
software runs only on platforms using Intel processors. Platforms using AMD processors are not supported.
BIOS Setting Recommendations
Ribbon recommends the following BIOS settings for optimum performance:
Recommended BIOS Settings for Optimum Performance
BIOS Parameter | Recommended Setting | Details |
---|
Intel VT-x (Virtualization Technology) | Enabled | For hardware virtualization |
Intel Hyper-Threading | Enabled | |
Intel Turbo Boost | Enabled | |
CPU power management | Maximum Performance | |
For example, the BIOS settings are shown below for HP DL 380p Gen8 servers. For BIOS settings of other servers, refer to the respective vendor's website.
BIOS Setting Recommendations for HP DL380p Gen8 Server
BIOS Parameter | Recommended Setting | Default Value |
---|
HP Power Profile | Maximum Performance | Balanced Power and Performance |
Thermal Configuration | Maximum Cooling | Optimal Cooling |
HW Prefetchers | Disabled | Enabled |
Adjacent Sector Prefetcher | Disabled | Enabled |
Processor Power and Utilization Monitoring | Disabled | Enabled |
Memory Pre-Failure Notification | Disabled | Enabled |
Memory Refresh Rate | 1x Refresh | 2x Refresh |
SBC SWe for KVM Hypervisor – Software Requirements
Following are KVM hypervisor and SBC SWe software requirements:
Software | Version | Tested or Qualified Version |
---|
KVM Module | 3.10.0 or above | 3.10.0 |
QEMU Emulator | 1.5.3 | 1.5.3 |
libvirtd (libvirt) | 1.1.1 | 1.1.1 |
virt-manager | 0.10.0 | 0.10.0 |
Downloading the SBC SWe Software Package
For more information, see Downloading the SBC SWe Software Package.
KVM Configuration Recommendations
KVM Configuration Recommendations
vCPU | Minimum 4 vCPUs required. Any number of vCPUs may be configured depending upon the call capacity requirements, but the number should be even (4, 6, 8, etc.) to avoid impacting performance. |
vRAM | Reserve the memory based on call capacity and configuration requirements. for supported call capacities with different configuration limits. |
Virtual Hard Disk | Set Hard Disk (virtual) size as 100 GB or more (based on requirements of retaining CDRs, logs, etc. for number of days). Note: Hard disk size cannot be changed after the SBC SWe software is installed. |
vNICs | Set number of virtual NICs as 4 (1-MGMT, 1-HA, 1-PKT0 and 1-PKT1). - Use only Virt-IO driver.