The network-wide licensing method uses licenses supplied by a centralized licensing server running within the EMS.
To configure D-SBC SWe for network wide licensing:
Select the D-SBC instance from the list appearing in the left pane. The SBC Configuration Manager page displays.
Click Administration > System Administration.
Select License Management > License Mode. The License Mode page displays.
Select Network from the Mode drop-down.
Click Save.
Click Save.
If using redundant EMS (EMS GR), create a license server for each EMS instance, with priority 1 for the source EMS and priority 2 for the target EMS.
Select the required license from the Feature Name drop-down.
Depending on the license selected, you may be prompted to enter the Min Count and Max Count.
Click Save.
Select Administration > System Administration > Platform Management and click Restart SBC Application.
After application restarts, click License Info List section to view the configured license information.
For more license information, refer to Managing SBC Licenses.
For more information on Alarms, refer to Licensing Alarms for SBC SWe Cloud.