You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

In this section:

Scenario

Establish configuration to prevent a subscriber from dialing international numbers

Background Information

The initial configuration is performed with the following background information:

  • System has been assembled and software installed at the factory.
  • System is cabled together (HA) and into the customer's network.

The 

Unable to show "metadata-from": No such page "_space_variables"
 defines the default instances for most profile objects.

The initial installation specifies the values for the following required entities:

  • Administrator account
  • Default system name
  • Two physical servers, or computing elements (CEs), with default names
  • Hardware link interfaces (ports) per server, with default names (pkt0 - pkt3)
  • Redundancy configuration
  • Management and HA interfaces IP address, net masks
  • Management Interfaces default Routes

The following procedure assumes that the management IP interfaces have already been configured as part of the

Unable to show "metadata-from": No such page "_space_variables"
setup.

Workflow

  1. Create a new Subscriber John Smith. Set DN to John Smith's telephone number.
  2. Create a new Class Of Service (COS) "Block International Calls".
    1. Set Call Blocking Service: enabled.
    2. Set Call Block Entry: 011* (international dial string)
  3. Associate Subscriber "John Smith" with COS created above. Set John Smith's COS reference to "Block International Calls".
  • No labels