The Overload Profile specifies a set of congestion thresholds, congestion durations, and overload controls. When a particular threshold is exceeded for a particular duration for any of the call processing related processes, the congestion level is raised to a higher level and the overload control is applied to help alleviate the congestion. The profile also specifies clear congestion thresholds and durations.

These values require that the overload conditions fall below their configured clear threshold values for a specific duration in order to return to the previous congestion level. These minimum clear durations prevent repeatedly switching in and out of congestion levels. You may assign an Overload Profile to the system (and apply it throughout the

Unable to show "metadata-from": No such page "_space_variables"
). You may specify and manage the following congestion criteria through this facility:

  • CPU utilization
  • Memory utilization

The following default Overload Profiles are automatically created for system congestion levels 1-3:

  • defaultMC1
  • defaultMC2
  • defaultMC3

You must disable an Overload Profile in order to change its configuration. Then, when you enable the profile, you cause all the parameter values to be validated. Once validated, these values are applied to the (system) congestion level that references the profile. When you make a change in this manner, the system congestion level is cleared if the Overload Profile was being referenced. Standby modules also perform congestion processing but you cannot configure the module settings.

To View Overload Profile

On SBC main screen, go to Configuration > Profile Management > Category: System Profiles >  Overload Profile.

The Overload Profile window is displayed.

Profile Management - System Profiles - Overload Profile

 

To Edit Overload Profile

To edit any of the Overload Profile in the list, click the radio button next to the specific Overload Profile name.

Profile Management - System Profiles - Overload Profile Highlighted

The Edit Selected Overload Profile window is displayed below.

Profile Management - System Profiles - Overload Profile Edit Window

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

To Create Overload Profile

To create a new Overload Profile, click New Overload Profile tab on the Overload Profile List panel.

Profile Management - System Profiles - Overload Profile Fields

The Create New Overload Profile window is displayed.

Profile Management - System Profiles - Overload Profile Create Window

The following fields are displayed:

Overload Profile Parameters

Parameter Description
Name

Overload Profile name. Use the following default profiles to create custom profiles:

  • defaultMC1
  • defaultMC2
  • defaultMC3
State

Administrative state of the Overload profile.

  • disabled (default) Set to "disabled" to change parameter values. While disabled, congestion processing continues to use the previous profile values.
  • enabled – Set to "enabled" to allow this profile to be referenced by a system congestion level whereby all parameter values are validated.

To Copy Overload Profile

To copy any of the created Overload Profile and to make any minor changes, click the radio button next to the specific Overload Profile to highlight the row.

Profile Management - System Profiles - Overload Profile Highlighted

 

Click Copy Overload Profile tab on the Overload Profile List panel.

Profile Management - System Profiles - Overload Profile Fields

 

The Copy Selected Overload Profile window is displayed along with the field details which can be edited.

Profile Management - System Profiles - Overload Profile Copy Window

 

The following fields are displayed:

Overload Profile parameters

Parameter

Description

Name

Overload Profile name. Use the following default profiles to create custom profiles:

  • defaultMC1
  • defaultMC2
  • defaultMC3
state

Administrative state of the Overload profile.

  • disabled (default) Set to "disabled" to change parameter values. While disabled, congestion processing continues to use the previous profile values.
  • enabled – Set to "enabled" to allow this profile to be referenced by a system congestion level whereby all parameter values are validated.
Set Threshold

Use this parameter to specify CPU and memory Set Threshold for a monitored resource.

  • cpu – CPU utilization percentage threshold at which the congestion level is set. (range: 0-100 / default = 85. A value of 0 disables CPU utilization as a congestion criterion.
Clear Threshold

Use this parameter to specify CPU and memory Clear Threshold for a monitored resource.

  • cpu – CPU utilization percentage threshold at which a congestion level is set or cleared. The clear threshold must be less than or equal to the set threshold. (range: 0-100 / default = 80).
Set Duration

Use this parameter to specify CPU and memory Set Duration for a monitored resource.

  • cpu – Length of time (in seconds) that CPU utilization percentage is above its set threshold before congestion level is set. (range: 0-65535 / default = 10). A value of zero sets the congestion level immediately.

Clear Duration

Use this parameter to specify CPU and memory Clear Duration for a monitored resource.

  • cpu -Length of time (in seconds) that CPU utilization percentage must be below its clear threshold before congestion level clears. A value of zero clears the congestion level immediately. (range: 0-65535 / default = 10).

Static Mode

Use this object to define the call accept percentage rate.

  • acceptPercentage – The rate (as percentage) to accept calls for the specified congestion level. (range: 0-100 / default = 100). A value of 0 rejects all calls. A value of 100 accepts all calls.

Make the required changes to the required fields and click Save to save the changes. The copied Overload Profile is displayed at the bottom of the original Overload Profile in the Overload Profile List panel.

To Delete Overload Profile

To delete any of the created Overload Profile, click the radio button next to the specific Overload Profile which you want to delete.

Profile Management - System Profiles - Overload Profile Highlighted

 

Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision.

Profile Management - System Profiles - Overload Profile Delete Confirmation

Click Yes to remove the specific Overload Profile from the list.

  • No labels