Sonus SBC 1000
The
Unable to show "metadata-from": No such page "_space_variables"
has three Ethernet ports used for communicating with the IP network. All SIP traffic is carried on these two ports. Unlike the SBC 2000, this model has no dedicated Management Port.
Sonus SBC 2000
The
Unable to show "metadata-from": No such page "_space_variables"
has four Ethernet ports and one Ethernet Management port. By default, each of the four non-management ports are in their own system created VLAN, and are isolated from one another.
ASM
If the unit is equipped with a built-in ASM, all ASM traffic is carried uniquely through this Ethernet port.
Working with Ethernet Ports:
- In the WebUI, click the Settings tab.
In the left navigation pane, go to Node Interfaces > Ports. See below for examples.
SBC 1000 - Ports
Ethernet Ports - SBC 1000 Example
SBC 2000 - Ports
Ethernet Ports - SBC 2000 Example
Ethernet Redundancy for Failover
Ethernet redundancy on the SBC 1000/2000 supports continued operation of the SBC if failures occur regarding the underlying Ethernet service, such as:
- Ethernet switch malfunction
- Ethernet port malfunction
By offering a standby Ethernet port to an active port, the
Unable to show "metadata-from": No such page "_space_variables"
allows SBC traffic to be re-directed from a primary Ethernet switch to an alternate Ethernet switch (within the same subnet) that is pre-configured (by the enterprise) with the same network connections as the primary Ethernet switch. The alternate switch is assumed capable of recognizing the introduction of live traffic to/from the SBC (over the standby Ethernet port) and to recover the outbound/inbound connections to the rest of the network.
Ethernet redundancy includes:
- A provisioning construct called Ethernet Redundancy Pair
Only one instance of pair will be supported by the SBC 1000 at any given time;
A maximum of two instances of pair will be supported by the SBC 2000 at any given time; - Any pair must be associated with two physically distinct Ethernet ports; on the SBC 2000, all Ethernet ports associated with one or two pair(s) must be unique;
- One port within the pair is selected as primary (carries all Tx and Rx to a primary Ethernet switch); the other is provisioned as the standby and is connected to an alternate Ethernet switch in the same subnet;
- The SBC will offer the provisioning of a single IP address to the pair, to "hide" from upper SBC application layers the Ethernet redundancy feature (i.e. only a single IP address may be assigned to the pair).
To configure Ethernet Port Redundancy, refer to the following pages for details:
To view a Ethernet Port's properties:
- Click the pop-up icon () next to the entry you want to view.
- When you are finished, close the window.
To delete an entry, select the checkbox next to the entry and then click the Delete () icon.
See also, Viewing Port Counters and Channel Details,