This section describes the dimensional, environmental, power, and network specifications and requirements for the
Unable to show "metadata-from": No such page "_space_variables"
System.

Not supported by SBC SWe Lite in this release.

Dimensions and Weight

Equipment

Height mm/in.

Width mm/in.

Depth mm/in.

Weight lb./kg

Chassis with no interface cards or expansion modules

42.00 / 1.65

441.60 / 17.38

299.00 / 11.77

8.50 / 3.85

Maximum supported configuration

(1RU) - 44 mm / 1.75 in

444 mm / 17.5 in.

305 mm / 12 in.

5.67 kgs / 12.5 lbs

Environmental Ranges (Operation and Storage)

Environmental Parameter

Specification

Operating Environmental Conditions

Temperature: 5º to 40º Celsius Humidity: 5% to 85% RH non-condensing Altitude: 60 meters below sea level to 1800 meters above sea level

Storage Environmental Condition

Temperature: -40º to 70º Celsius

Cooling System

Internal forced convection

Power Supply

Unknown macro: {multi-excerpt-include}
For more information about the 
Unable to show "metadata-from": No such page "_space_variables"
power supply units, see Ribbon SBC 1000-2000 System Power Supplies.

Ethernet Port Pinouts

The 10/100/1000 Base-T port pinouts are as follows:

Ethernet Port

 

 

Ethernet Connector Pinouts

Pin Number

SignalDefinitionColor
1TX +Transmit DataWhite w/orange
2TX -Transmit DataOrange
3RX +Receive DataWhite w/green
4RSVDReservedBlue
5RSVDReservedWhite w/blue
6RX -Receive DataGreen
7RSVDReservedWhite w/Brown
8RSVDReservedBrown


Additional Resources